Product Features; High Elevations; Gas Pressures; Gas Specifications & Orifice Size - Monessen Hearth IDV SERIES IDV380NVC Installation And Operating Instructions Manual

Idv series direct vent gas fireplace insert
Table of Contents

Advertisement

PRODuCt FeAtuReS

PRODuCt SPeCiFiCAtiONS
This appliance has been certified for use with
either natural or propane gas. Refer to the
appropriate data plates.
This appliance is not for use with solid
fuels.
The appliance is approved for bedroom or
bedsitting room installations.
The appliance must be installed in accor-
dance with local codes if any. If none exist
use the current installation code. ANSI
Z3.1/NFPA 54 in the USA, CSA B149 in
Canada.
The appliance must be properly connected
to a venting system.
this appliance may be installed in an
aftermar ket *, p e rma ne nt l y l oc a t e d ,
manufactured home, where not prohibited
by local codes
*Aftermarket: Completion of sale, not for purpose of resale,
from the manufacturer.

hiGh eleVAtiONS

Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z3.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).

GAS PReSSuReS

Inlet Minimum
Inlet Maximum
Manifold Pressure
57D0016
Natural
Propane (LP)
4.5" w.c.
11.0" w.c.
10.5" w.c.
13.0" w.c.
3.5" w.c.
10.0" w.c.
Optional
Remote
Receiver
Blower Knob
ON/OFF Switch
Piezo Igniter
HI/LO Knob
Figure 1 -
IDV Series Fireplace Insert
GAS SPeCiFiCAtiONS & ORiFiCe SiZe
Model
IDV380NVC
IDV380PVC
IDV490NVC
IDV490PVC
The IDV Series gas inserts are equipped with a variable
speed output gas control.
NOte: IDV Series gas inserts operate without any elec-
trical supply. Blower must be attached to 110/10V AC.
IDV380/IDV490 Fireplace Insert
Gas Shut-Off
Valve
OFF/Pilot/ON
Knob
FP2621
IDV controls
Max.input Min. input
Fuel
Btu/h
Btu/h
Nat.
30,500
0,500
LP
8,000
,000
Nat.
40,000
6,500
LP
37,500
9,000
FP61
On/Off
Remote
Switch
Orifice
Size
#35
#53
#30
#50
5