Can Connector (X1, X2); Flexray Connector (X3, X7) - Fujitsu SK-91465X-100PMC User Manual

Table of Contents

Advertisement

5.4 CAN Connector (X1, X2)

Two 9-pin D-Sub male connectors are used for the CAN interfaces CAN0 and CAN4.
Pin Number
Pin Signal
1
NC
2
CANL
3
GND
4
NC
5
NC
6
NC
7
CANH
8
NC
9
NC
Shield
GND

5.5 FlexRay Connector (X3, X7)

Two 9-pin D-Sub male connectors are used for the two FlexRay channels A and B.
Pin Number
Pin Signal
1
NC
2
BM
3
GND
4
NC
5
User
6
NC
7
BP
8
NC
9
NC
Shield
Shield
© Fujitsu Microelectronics Europe GmbH
SK-91465X-100PMC User Guide
Chapter 5 Connectors
Figure 5-3: CAN Connector
Description
Not used
LOW-level CAN voltage input/output
Ground
Not used
Not used
Not used
HIGH-level CAN voltage input/output
Not used
Not used
Ground
Table 5-3: CAN Connector Signals
Figure 5-4: FlexRay Connector
Description
Not used
Bus line Minus
Ground
Not used
Connected to Jumper (CH-A: JP30; CH-B: JP17)
Not used
Bus line Plus
Not used
Not used
Connected to GND via Jumper
(CH-A: JP39; CH-B: JP23)
Table 5-4: FlexRay Connector Signals
- 29 -
UG-910056-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents