The following table lists the power consumption for the
DECstation base system.
NOTE
The reserve current row indicates the amount of current
that is available for options and may be distributed
between the other slots as needed.
Table A–1 DECstation Base System Power Consumption
+5
Volts
Current
Amps
Available
20.00
current
Current
5.300
required
Reserve
14.70
current
Power
26.50
consumed
Power
—
available
Power Consumption
-12
+12
Volts
Volts
Amps
Amps
0.30
8.00
0.030
0.039
0.27
7.96
0.15
0.20
—
—
A
DC
+12
Power
Peak
Amps
(VA)
9.00
—
—
—
9.00
—
—
26.84
—
173.15
A–1