Lipo, Lilon, Life, Nicd, Nimh, Pb Battery Charge Processes; Charge Mode Per Battery Type - GRAUPNER POLARON PRO Operating Manual

Hide thumbs Also See for POLARON PRO:
Table of Contents

Advertisement

Available languages

Available languages

Below picture shows the sequence of charging.
13.4 LiPo, Lilon, LiFe, NiCd, NiMH, Pb battery charge process

13.5 Charge mode per battery type

[ AUTOMATIC ]
NiCd/NiMH : This step is an automatic charging process, first determining the number of cells and then monitoing
the charge current. The charger calculates the internal resistance and charge current for every period of time,
automatically adjusting the charge current to ensure the delivery of the optimal charge current to your pack.
The PEAK SENS values (NiCd=7mV/cell, NiMH=4mV/cell) are applied automatically. The CUT-TEMP values can be
programmed.
[ NORMAL ]
NiCd/NiMH: The charger will charge the pack with a preset charge current, stopping the charging process every minute
to calculate the voltage and detect the Delta peak. This process allows for improved peak detection, determining
the amount of battery wear and instabilties in the charge cable.
The charger verifies the connection with the balance
board. This step is an automatic process.
CHARGE MODE SELECTION
Both the charge mode and the delay time are programmed
parameters.
To activate, tap the box to become blue. Tap the DEC/INC button to select
the desired mode.
Charge modes are explained below After a 5-second countdown,
the charger initiates the charging process.
Tapping the Enter
immediately.
DELAY TIME SETUP
The Start Delay Time can be set at values ranging from
1-150 minutes.
The charger initiates the battery charging process
after preset time has expired.
button initi - ates the charging process