Special Vent Installations; Periscope Termination; Corner Termination - Napoleon GDS60-1N Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

3.3

SPECIAL VENT INSTALLATIONS

3.3.1 PERISCOPE TERMINATION

Use the periscope kit to locate the air termination above grade. The periscope must be installed so that
when fi nal grading is completed, the bottom air slot is located a minimum 12" (304.8mm) above grade. The
maximum allowable vent length is 10' (3.1m) for a fi replace and 8' (2.4m) for a stove.
24" (610mm)
MINIMUM

3.3.2 CORNER TERMINATION

The maximum vent length for a corner installation is 24" (609.6mm).
12"
(305mm)
MIN. TO
GRADE
30 1/2" (775mm)
2 4 "
0 " (
CORNER INSTALLATION
29" (737mm)
MINIMUM
)
m m
( 6 1 0
M
I M U
M A X
E
) R I S
0 m m
13
12"
(305mm)
MIN. TO
GRADE
9.4A
W415-1328 / A / 01.05.16
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs60-1nGds60-1pGs60-1p

Table of Contents