Axis Multicable C I/O Audio Power 1 M/ 5 M (Sold Separately) - Axis P5635–E User Manual

Ptz dome network camera
Hide thumbs Also See for P5635–E:
Table of Contents

Advertisement

AXIS P5635–E PTZ Dome Network Camera
Technical Specifications
Included
RJ45 Push-pull Connector (IP66), Hard ceiling mount, Spring pipe adaptor, U-profile pipe adaptor, Installation Guide,
accessories
Windows decoder 1-user license, AVHS Authentication key
Optional
AXIS T91B Mounts, AXIS T94A02L Recessed Mount, Outdoor RJ45 cable with premounted connector,
accessories
AXIS T8133 Midspan 30 W 1-port, Repaintable skin covers
Smoked Dome, Axis 10-pin Push-pull System Connector, Axis Multicable C I/O Audio Power 1 m/5 m
Video
AXIS Camera Companion, AXIS Camera Station, Video management software from Axis' Application Development
management
Partners available on www.axis.com/techsup/software
software
Languages
German, French, Spanish, Italian, Russian, Simplified Chinese, Japanese, Korean, Portuguese
Warranty
Axis 3-year warranty and AXIS Extended Warranty option, see www.axis.com/warranty
a. This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit. (www.openssl.org), and
cryptographic software written by Eric Young (eay@cryptsoft.com).
More information is available at www.axis.com

Axis Multicable C I/O Audio Power 1 m/ 5 m (sold separately)

When connecting external equipment to the Axis product, an Axis Multicable C I/O Audio Power 1 m/ 5 m (sold separately) is
required in order to maintain the product's IP rating.
Connect the multicable to the product's multi-connector. To locate the multi-connector, see Hardware Overview on page 7 .
The multicable provides the following connectors:
Power connector - 2-pin terminal block used for AC or DC power input. Use a Safety Extra Low Voltage (SELV) compliant limited
power source (LPS) with either a rated output power limited to ≤100 W or a rated output current limited to ≤5 A.
Function
AC/DC Power
input
Audio connector - 4–pin terminal block used for audio in and audio line out. This can be connected to a public address (PA) system
or an active speaker with a built-in amplifier.
Function
Audio In
Audio Line Out
GND
Pin
Notes
Polar-
Use a Safety Extra Low Voltage (SELV) compliant limited
ity in-
power source (LPS) with either a rated output power limited
depen-
to ≤100 W or a rated output current limited to ≤5 A.Ground
dent
for AC/DC
Pin
Notes
1
Balanced or unbalanced input for a mono microphone or line signal
3
Can be connected to a public address (PA) system or an active speaker with a built-in
amplifier
2, 4
Ground
66
Specifications
24 V AC/DC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P5635-e

Table of Contents