Table 21. UNIX LLI driver messages for the Ethernet controller
pnt0-7
Cannot allocate memory for the adapter during reset. Please check your Streams parameters.
Explanation: The system is out of Streams memory blocks. Action: Use the CRASH utility to
increase the number of Streams memory blocks.
pnt0-11
Device not found!
Explanation: The driver cannot find an Ethernet controller. Action: Verify that the Ethernet
controller is enabled. If the Ethernet controller is enabled, run the diagnostic programs.
pnt0-12
Device failed checksum test!
Explanation: The driver cannot find an Ethernet controller. Action: Verify that the Ethernet
controller is enabled. If the Ethernet controller is enabled, run the diagnostic programs.
pnt0-13
add_intr_handler failed! Interrupts already enabled.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server. Action: Modify your hardware settings.
pnt0-14
Cannot locate hardware.
Explanation: The SunSoft Solaris driver cannot find any Ethernet controller. Action: Verify that
the Ethernet controller is enabled. If the Ethernet controller is enabled, run the diagnostic
programs.
pnt0-15
No more devices to open.
Explanation: The SunSoft Solaris driver cannot find any more Ethernet controllers. Action:
Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the
Ethernet adapter that fails to respond. If the problem persists, run the diagnostic programs.
pnt0-17
Device fault...Reset initiated!
Explanation: The SunSoft Solaris driver has been reset due to a device fault. Action: Verify that
additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the Ethernet
adapter that fails to respond. If the problem persists, run the diagnostic programs.
pnt0-19
IRQ found for PCnet hardware does not match space.c (or pnt.conf)!
Explanation: This is a warning message referring to the interrupt request (IRQ) that the SunSoft
Solaris driver found in the system. Action: Ignore this message if you are sure that this is what
you want to do. Otherwise, run the NETCONFIG program to match the hardware settings
pnt0-20
add_intr_handler failed! Unknown interrupt type.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server. Action:
•
•
pnt0-21
add_intr_handler failed! Out of range interrupt number.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server. Action:
•
•
add_intr_handler failed! Out of range IPL.
pnt0-22
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server. Action: Modify your hardware settings. Run the NETCONFIG
program to search for another Ethernet controller.
112
IBM® xSeries 150 : User's Reference
Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.