Cod
Function
e
089
Microprocessor
88
IBM® xSeries 150 : User's Reference
Result
Failed
Invalid microprocessor in slot xyz or BIOS setup
problem
(where xyz identifies the microprocessor that is
causing the error message)
Processor in socket id xyz is installed but not
functioning
(where xyz identifies the microprocessor that is
causing the error message)
Microprocessor in socket id xyz
(where xyz identifies the microprocessor that is
causing the error message)
Note:
The Microprocessor Error LED associated
with the microprocessor will be lit.
Processor in socket id xyz is defective
(where xyz identifies the microprocessor that is
causing the error message)
Text message
Action
1. Check the system
error log for the
related error
messages.
2. If your server does
not have the latest
level BIOS
installed, update
the BIOS.
3. If the problem
remains, replace the
xyz microprocessor
and run the test
again.
If the problem persists,
call for service.
1. Reseat the
microprocessor.
2. If the problem
remains, replace the
microprocessor.
If the problem persists,
call for service.
Replace the
microprocessor.
If the problem persists,
call for service.