Mitsubishi Electric MR-J3-T Quick Start Manual page 21

Servo amplifier with point table positioning
Hide thumbs Also See for MR-J3-T:
Table of Contents

Advertisement

Positioning with Digital Inputs
A 24V 1000mA power supply can be
used for all control terminals.
Fig. 4-3:
NOTES
You can find a brief descriptions of the signal functions in Appendix A.1. Please refer to the
instruction manual for a complete reference.
All digital signals described in this manual use source logic.
For safety reasons the EMG signal must be connected to pin 1 of connector CN6 if the
servo amplifier is not operated during the first functional test. The EMG signal is perma-
nently assigned to pin 1 and the amplifier is deactivated when there is no EMG signal if it is
configured accordingly (see chapter 3.2).
MR-J3-T
24V DC ±10%
24V DC
150mA
EMG. OFF
Proximity dog
Forward stroke end
Reverse stroke end
MR-J3USBCBL3M
24V DC ±10%
24V DC
800mA
Point
table
selection
SERVO ON
RESET
Automatic/Manuall
Forward rotation start
Reverse rotation start
Connection of the control terminals with PNP logic (source logic)
max. 10m
(Option)
max.10 m
Additional Connections
max. 10m
Alarm code
In position
max. 10m
4 - 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents