Ice Thickness Sensor - Scotsman C2648 Service Manual

Modular cuber induding prodigy plus
Hide thumbs Also See for C2648:
Table of Contents

Advertisement

C2648 Prodigy and Prodigy Plus Service Manual

Ice thickness sensor

1. Push and release the Off switch.
2. Remove front and top panels.
3. Push and release the Harvest switch
4. Remove the evaporator cover.
5. Disconnect electrical power.
6. Open the control box.
7. Remove left most curtain.
8. Locate sensor, squeeze mounting legs together to
release it from the mounting bracket.
9. Remove sensor, follow wire back to control box.
10. Disconnect from controller connection J10.
11. Remove sensor from machine.
12. Reverse to reassemble.
13. Set initial probe-to-evaporator-surface gap using a 7/32" drill bit as a gauge. Bridge thickness adjustments
may be needed. Operate machine and to confirm and adjust ice bridge.
Electrical Shock Hazard
Disconnect electrical
power before beginning
January 2015
Page 60