Use And Operation - Scotsman C2648 Service Manual

Modular cuber induding prodigy plus
Hide thumbs Also See for C2648:
Table of Contents

Advertisement

C2648 Prodigy and Prodigy Plus Service Manual

Use and Operation

Once started, the ice machine will automatically
make ice until the bin or dispenser is full of ice. When
ice level drops, the ice machine will resume making
ice. There are four indicator lights at the front of the
machine that provide information on the condition of
the machine.
External Indicator Lights:
• Power
• Status
• Water
• Clean
Steady Green
Blinking Green
Blinking Red
Yellow
Blinking Yellow
Light off
If the Water light is on, the machine has sensed a
lack of water. Check the water supply to the machine.
The water may have been shut off or the water filter
cartridges need to be changed.
If the Clean light is on, the machine has determined
that it may need to be cleaned. Contact an authorized
Scotsman service agent and have the machine
cleaned, de-scaled and sanitized.
Other Indicators
Removal of the front panel allows review of the Code
Display and Component Indicator Lights.
Note: A Component Indicator Light switches ON
to indicate that the component is operating.
Note: There are three Curtain Switch lights, SW1,
SW2 and the Period in the display code. A curtain
switch light is ON when a curtain is either open or not
present.
Indicator Lights & Their Meanings
Power
Status
Normal
Normal – bin full or
making ice
Self Test Failure
Switching on or off
-
Diagnostic
shutdown or,
if making ice,
temperature sensor
failure
-
-
-
-
No power
Switched off
Water
-
-
Lack of water
-
-
Normal
January 2015
Page 18
De-Scale & Sanitize
-
-
-
Time to de-scale
and sanitize
In Cleaning mode
Normal