Figure
.
.
he power cord is now disconnected from the blower
control plate. Pull the cord out through the right side
of the appliance.
Grommet
Route Cord Through
Retainer Clip
Figure
.2
. nsert the power cord throught the left side of the
appliance in the hole contains the grommet. Pull the
connection ends to the right side. Route the power
cord through the retainer clip.
Figure
.3
10. Replace the strain relief on the power cord in the
same position as before. Locate the indentation on
the cord made by the strain relief.
push the strain relief back into the control plate.
May 23, 2013
11. Connect the white wire on the power cord into the
12. nsert the control plate assembly back into the
Strain Relief
13. Push in the blower and hold down bracket into
nce replaced,
7075-166C
White Wire
Fiber
Wrapped
Wire
Figure
.
black wire on the power cord to the white wire on the
rheostat. Re-attach the green ground terminal to the
control plate.
Figure
.
appliance as shown. ilt the assembly forward and
then lift up and rotate the bottom towards the front
of the appliance at the same time ensure that the
snap disc holder is properly seated. Secure plate
to the appliance.
Route Wires through Retainer Clip
Replace Screws in Hold Down Bracket
Figure
.
appliance matching up the tab on the bracket and
placement slot on the appliance. Secure bracket
er
Black Wire
Green
Grounding
Wire