Hose and Regulator (used with gas cylinder):
1. Where applicable a pressure hose and regulator assembly supplied with the Rinnai
Luminaire Outdoor Gas Fire are suitable for use on bottled LP gas only.
2. The pressure regulator and hose assembly supplied with the appliance MUST be used.
3. Replacement pressure regulators and hose assemblies must be those specified by Rinnai for use
with this appliance.
4. The pressure regulator supplied has been fixed to have an outlet pressure of 2.75 kPa. 
A different pressure is not suitable.
5. Propane or universal LP gas cylinders must be installed and positioned to conform with 
AS 5601, Appendix J - "LP Gas Cylinders".
6. When the appliance is not in use, the hose and regulator must only be disconnected from the
cylinder. The hose and regulator must not be disconnected from the unit unless it is being
replaced. Such replacement must only be carried out by an authorised person.
7. Inspect the gas hose when replacing the gas cylinder, or once per year, whichever is more
frequent. If the hose is cracked, cut, abraded, discoloured or damaged in any other way, the Rinnai
Luminaire Outdoor Gas Fire must not be used. The hose must be replaced if damaged or when
local regulations require this. Contact your supplier or local regulating authority if uncertain. Such
replacement must only be carried out by an authorised person.
Gas Cylinder
1. This Rinnai Luminaire Outdoor Gas Fire is designed for use with a 9 kg LP Gas cylinder.
This cylinder should conform to AS 2030.1 - 1999.
2. The Rinnai Luminaire Outdoor Gas Fire is designed for use in the vapour withdrawal mode.
Therefore it is important to always store and use the gas cylinder in an upright position.
3. For storage and when refilling / exchanging cylinders, disconnect the hose and regulator at the
cylinder end only. DO NOT disconnect the hose and regulator from the appliance end.
4. The gas cylinder should be refilled by a reputable gas dealer, or exchanged at a reputable gas
cylinder exchange outlet. Gas cylinders should be inspected and re-qualified periodically in
accordance with local statutory regulations. A dented or rusty gas cylinder may be hazardous and
should not be used.
5. DO NOT subject the gas cylinder to excessive heat.
6. Always close the cylinder valve when this unit is not in use.
7. Gas cylinders must be stored outdoors in a well ventilated area out of reach of children and must
not be stored in a building, garage or any other enclosed area.
8. When in use Gas Cylinders must be installed and positioned to conform with AS 5601 Appendix J -
"LP Gas Cylinders".
Rinnai Australia
SAFETY INFORMATION
- 5 -
Rinnai Luminaire® Outdoor Gas Fire - Operation and Installation Manual