Appliance Location - Rinnai ROF4500 Operation & Installation Manual

Luminaire outdoor gas fire
Table of Contents

Advertisement

The Rinnai Luminaire Outdoor Gas Fire must be installed as a permanent fixture in an outdoor area.
Determining and consideration of the position for the Rinnai Luminaire Gas Outdoor Fire will be
dependent on the configuration of the unit purchased. Additional considerations such as protection
from direct rain, wind and sea spray, openable windows, debris from trees as well as location to
neighbouring properties also needs to be considered, gas supply and clearances from combustibles
will influence where you can position this appliance. 
Location will also be depended on the type of unit purchased and if being installed into a combustible
cavity.
General Clearances
Inbuilt
A
C
B
E - min. 100mm
Minimum of 2 x 200 cm
One at the top of the storage area and one at the base.
Structure
Below eaves,
balconies or other
1000 mm minimum
projections (A)
Inbuilt - 100 mm minimum 
From the ground or
other surface (E)
Freestanding - 900 mm minimum
Walls (D)
500 mm
Gas Meters
1000 mm
Drain of Soil Pipe
150 mm
Openable Windows
1000 mm
and doors
Mechanical Air Inlet
2000 mm
Mantles (B) and (C)
500 mm / 300 mm
Fixed objects such as outdoor furniture, umbrellas and plants should be at least 1 m away
1 m safe distance
from the unit when it is in operation.
Installation specific
Additional clearances also need to be observed for specific installation applications, these
clearances
are detailed on the following pages.
Ensure clearing for
Ensure enough room is maintained for servicing, cleaning and general access to the
servicing
appliance.
When using a 9 kg gas cylinder a minimum of 2 x 200 cm
Ventilation of structure
(1 x top and 1 x bottom = 400 cm
cylinders.
Rinnai Australia

APPLIANCE LOCATION

300mm
D
2
ventilation slots to be incorporated into the structure.
Clearances Required
- 14 -
Freestanding
1m
600mm
Max.
Additional Detail
If the projection is a shade cloth or material awning
then this is deemed as a combustible material and
the recommended clearance is 1500 mm.
Ground level to bottom of fireplace.
Side of unit to side wall.
From an openable window, door or non mechanical
air inlet, or any other opening into a building with the
exception of sub-floor ventilation.
For example: air conditioning unit.
Minimum vertical clearance of 500 mm with a
maximum mantle depth of 300 mm. If mantle depth
is more than 300 mm you will need 1000 mm of
vertical clearance.
2
2
total) to ensure safe ventilation of all structures housing
Rinnai Luminaire® Outdoor Gas Fire - Operation and Installation Manual
1m
300mm
E
= 900mm Min.
1m
ventilation slots must be used