SAFETY INFORMATION CONTINUED
General Safety Information
Failure to comply with these Instructions could result in a fire or explosion
which could cause serious injury, death or property damage.
WARNING
This appliance must be installed and commissioned by an authorised person
only.
This is a permanently fixed luminous effect appliance for outdoor areas only.
Not to be used for cooking, food preparation or food warming.
If you smell gas:
1. Shut off gas to the appliance, at its source if possible.
WARNING
2. Extinguish any open flame.
3. Perform gas leak check procedure.
4. If odour continues, immediately call Rinnai service person refer page 23.
Never connect the appliance directly to the gas cylinder / reticulated gas supply
without a Regulator.
WARNING
Always use the hose and regulator supplied (Universal LPG models only).
Never store your gas cylinder indoors. Gas cylinders must be stored outdoors
in a well ventilated area out of reach of children or the infirm.
DO NOT test for gas leaks with an open flame.
DO NOT allow children or the infirm to operate or handle any parts of the
appliance.
Before Installation
Check that the Rinnai Luminaire Outdoor Gas Fire supplied is correct for the gas type being used. The
gas type is clearly labelled on the appliance. Dataplate is located under left hand stone cover.
Appliance is labelled "Universal LPG", or "Natural Gas". Label is located under right hand stone cover.
If the appliance is "Universal LPG" it is normally used with a 9 kg gas cylinder. However, it is possible
to install appliance on a reticulated "Universal LPG" supply. ie. 45 Kg. cylinder domestic supply.
Pipe sizing for reticulated Natural or Universal LPG gas supplies must be in accordance with an
approved sizing chart such as the one in AS 5601.
Natural Gas:
1. Must be connected to the reticulated supply either by hard plumbing or the use of an
approved hose.
2. Must be installed with the pressure regulator supplied for Natural Gas.
3. Connection to the reticulated gas supply must incorporate an isolation valve.
4. The isolation valve must be closed when the Rinnai Luminaire Outdoor Gas Fire is not in use.
Ensure all PVC plastic coating material is removed before operating unit.
WARNING
Rinnai Australia
- 4 -
Rinnai Luminaire® Outdoor Gas Fire - Operation and Installation Manual