H. Securing Chimney Components
All joints should be secured with 3 sheet metal screws or
rivets per pipe manufacturers instructions. The sections must
be attached to the insert and to each other with the crimped
(male) end pointing toward the insert. Figure 4.9.
LINER CONNECTOR
CRIMPED
END
TOWARDS
STOVE
Figure 4.9
WARNING
Fire Risk.
Follow venting manufacturer's clearances and
instructions when installing venting system.
WARNING
Fire Risk.
Do NOT pack insulation or other combustibles
between spacers.
• ALWAYS maintain specified clearances around
venting and spacers.
• Install spacers as specified.
Failure to keep insulation or other material away from
vent pipe may cause fire.
WARNING
Fire Risk.
This appliance relies upon natural draft to operate
properly.
• Chimney heights exceeding 25 feet (7.62m)
from base of appliance may create an over-draft
situation.
• Overdraft condition may create over-firing.
Over-firing may ignite creosote and/or damage
appliance and chimney
Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15