Getting Started; Design And Installation Considerations; Fire Safety - Quadra-Fire Adventure-III Installation Manual

Hide thumbs Also See for Adventure-III:
Table of Contents

Advertisement

2

Getting Started

A. Design and Installation Considerations
Consideration must be given to:
• Safety
• Convenience
• Traffic flow
• Chimney and chimney connector required
It is a good idea to plan your installation on paper, using exact
measurements for clearances and floor protection, before
actually beginning the installation. If you are not using an
existing chimney, place the appliance where there will be a
clear passage for a factory-built listed chimney through the
ceiling and roof.
We recommend that a qualified building inspector and your
insurance company representative review your plans before
and after installation.
If this appliance is in an area where children may be near it
is recommended that you purchase a decorative barrier to go
in front of the appliance. Remember to always keep children
away while it is operating and do not let anyone operate
this appliance unless they are familiar with these operating
instructions.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult insurance carrier, local building, fire officials or
authorities having jurisdiction about restrictions, installation
inspection, and permits.
WARNING
Asphyxiation Risk.
• DO NOT CONNECT THIS APPLIANCE TO A
CHIMNEY FLUE SERVICING ANOTHER APPLI-
ANCE.
• DO NOT CONNECT TO ANY AIR DISTRIBUTION
DUCT OR SYSTEM.
May allow flue gases to enter the house.
4
Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15
Install Guide
B. Fire Safety
To provide reasonable fire safety, the following should be
given serious consideration:
1. Install at least one smoke detector on each floor of
2. A CO detector should be installed in the room with the
3. A conveniently located Class A fire extinguisher to
4. A practiced evacuation plan, consisting of at least two
5. A plan to deal with a chimney fire as follows:
Negative pressure results from the imbalance of air avail-
able for the appliance to operate properly. It can be stron-
gest in lower levels of the house.
Causes include:
• Exhaust fans (kitchen, bath, etc.)
• Range hoods
• Combustion air requirements for furnaces, water heaters
• Clothes dryers
• Location of return-air vents to furnace or air conditioning
• Imbalances of the HVAC air handling system
• Upper level air leaks such as:
NOTICE: HEARTH & HOME TECHNOLOGIES ASSUMES NO
• Downdrafts
• Tight sealing construction of the structure
• Mechanical exhausting devices
• Overdrafting caused by excessive chimney heights
• Ideal performance is with height of chimney between 14-16 feet
your home to ensure your safety. They should be
located away from the heating appliance and close
to the sleeping areas. Follow the smoke detector
manufacturer's placement and installation instructions,
and be sure to maintain regularly.
appliance.
contend with small fires resulting from burning embers.
escape routes.
In the event of a chimney fire:
a
Evacuate the house immediately
b. Notify fire department
and other combustion appliances
- Recessed lighting
- Attic hatch
- Duct leaks
RESPONSIBILITY FOR THE IMPROPER PERFORMANCE
OF THE APPLIANCE SYSTEM CAUSED BY:
Inadequate draft due to environmental conditions
(4.26-4.88m) measured from the base of the appliance.