BY-PASS TRAY
By-pass
tray
Paper size PS1 (PS55)
Paper size
PS2 (PS56)
Paper size
detection
VR (VR4)

[3] First Paper Feed Control

24VDC
SD11 CONT
24VDC
24VDC
M6 DRIVE A
M6 DRIVE A
M6 DRIVE B
M6 DRIVE B
PRCB
The 1st paper feed from the by-pass tray takes place as
the result of the transmission of the drive force from M6
(loop roller) to the paper feed roller. SD11 (pick up (by-
pass tray)) moves up and releases the paper feed roller
contacting to the paper after the roller picked up and
fed the first paper to the feed roller side to facilitate
paper feeding.
The above operations are controlled by the PRCB
(printer control board).
1. Operation
a.
First paper feed operation timing
Controlled at M6 ON/OFF timings and by M6
rotation direction.
2. Signals
a.
Output signals
(1) SD11 (PRCB to SD11)
SD11 drive control signal (bypass tray).
[L]: SD11 ON
[H]: SD11 OFF
(2) M6 DRIVE A, A (PRCB to M6)
M6 A-phase drive control pulse signal.
(3) M6 DRIVE B, B (PRCB to M6)
M6 B-phase drive control pulse signal.
2-L-2
SD11
M6
24VDC
24VDC
PGND
PGND
DCPS2