Dmax Control - Minolta Di850 Service Manual

Hide thumbs Also See for Di850:
Table of Contents

Advertisement

DEVELOPING UNIT

[6] Dmax Control

24VDC
24VDC
DCPS2
12VDC
DCPS1
TH5
Dmax control is performed by the TCSB (toner
control sensor board), M2 (drum), M3 (develop-
ing), and so on. These parts are controlled by the
PRCB (printer control board). Related boards
and sensors are DPSB (drum potential sensor
board), DPS (drum potential sensor), and TH5
(drum temperature sensor).
When the front right or left door of this machine
opens or closes, MS1 (interlock 1) or MS2 (inter-
lock 2) operates to interrupt the DC power supply
to the motor, stopping the M2 and M3.
MS2
MS1
PGND
5VDC
SGND
TH5 ANG1
TH5 ANG2
Dmax LED CONT
/Dmax LED Vref
JAM LED CONT
PRCB
M2
M2 CONT
M2 F/R
SGND
M2 EM
M3
M3 CONT
M3 CLK
M3 EM
DPS DRIVE A
DPS DRIVE B
DPS ANG 1
DPS ANG
DPS ANG 2
AGND
DPSB
5VDC
Dmax SIG
Dmax MONI
JAM SIG
TCSB
1. Operation
The purpose of Dmax control is to adjust the
maximum density to the reference level for each
machine.
a.
Dmax control
(1) Method
Latent images are created several times at the
maximum exposure level, images are developed
with the rotational speed of the developing
sleeve varied, then each density is read by the
Dmax sensor (PD1) on the TCSB.
The developing sleeve speed detected when the
density has reached the reference level is
recorded as the optimum sleeve speed and the
developing is performed at this optimum sleeve
rotation speed.
(2) Timing
a) When the fixing temperature is lower than
50°C at power ON.
b) At the end of job after every 20,000 copies.
2-G-4
DPS

Advertisement

Table of Contents
loading