Electrical Adjustments
Group/
Item Name
Item
30 cSatMin
31 cSatMax
32 wCoeMin
33 wCoeMax
Group 230 VBI Slice Level
0 Generic Initial Slice Level
1 Generic High Level Threshold
2 Generic Low Level Threshold
3 Generic Minimum Low Level
4 Generic Maximum High Level
Group 250 FAN Voltage Adjutment
0 Fan1 Min. Adjust (DAC)
1 Fan1 Max. Adjustt(DAC)
2 Fan2 Min. Adjust (DAC)
3 Fan2 Max. Adjust (DAC)
4 Fan3 Min. Adjust (DAC)
5 Fan4 Max. Adjust (DAC)
6 Not used
7 Not used
Group 252 Fan Option
0 Hi-Land Switch
1 Safety Switch
2 Fan Manual Switch
3 Fan1 Manual Voltage
4 Fan2 Manual Voltage
5 Fan3 Manual Voltage
6 Not used
Group 253 FAN Error Setting
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
7 Temp C Warning (Normal)
8 Temp B-A Waninig (Normal)
9 Temp C-A Warning (Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
12 Temp C Warning (Eco)
13 Temp B-A Waninig (Eco)
14 Temp C-A Warning (Eco)
15 Temp A Warning Offset (Temp)
16 Temp B Warning Offset (Temp)
17 Temp B Warning Offset (Temp)
18 Temp B-A Warning Offset (Temp)
19 Temp C-A Warning Offset (Temp)
20 Temp A Warining Offset (Time)
21 Temp B Warning Offset (Time)
22 Temp B Warning Offset (Time)
23 Temp B-A Warning Offset (Time)
24 Temp C-A Warning Offset (Time)
Group 254 FAN Control Range Setting
10 Normal Fan Control Min. Temp
11 Normal Fan Control Max. Temp
12 Normal Fan1 Min.
13 Normal Fan1 Max.
14 Normal Fan2 Min.
15 Normal Fan2 Max.
16 Normal Fan3 Min.
Function
0: Normal
1: Hi-Land Mode "On1"
2: HiLand Mode "On2"
For Safety Application purpose
0: Auto, 1: Manual
Fan Voltage (x0.1V)
Fan2 Voltage (x0.1V)
Fan3 Voltage (x0.1V)
Temperature A to judge the Temp. Failure
Outside at Normal
Temperature B to judge the Temp. Failure
Panel at Normal
Temperature C to judge the Temp. Failure
Lamp at Normal
Temperature B-A to judge the Temp. Failure
Filter Cloggled at Normal
Temperature C-A to judge the Temp. Failure
Filter Cloggled at Normal
Temperature A to judge the Temp. Failure
Outside at Eco
Temperature B to judge the Temp. Failure
Panel at Eco
Temperature C to judge the Temp. Failure
Lamp at Eco
Temperature B-A to judge the Temp. Failure
Filter Cloggled at Eco
Temperature C-A to judge the Temp. Failure
Filter Cloggled at Eco
Temp Sensor Control Start/End at Normal
Fan Voltage at Normal (x0.1V)
Initial
53
203
400
1000
9
0
0
0
255
28
205
36
207
30
235
0
0
100
100
100
A
B
C
D
43
43
40
40
52
52
52
52
60
60
55
55
100
100
100
100
100
100
100
100
42
42
40
40
54
54
50
50
60
60
52
52
100
100
100
100
100
100
100
100
5
5
10
0
0
3
3
3
3
3
A
B
C
D
35
35
32
32
40
40
38
38
65
65
125
125
135
135
135
135
65
65
90
90
120
120
135
135
77
77
85
85
-42-
Range
Note
0 - 255
0 - 255
0 - 1000
0 - 1000
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 2
Read only
0,3-6
0 - 1
0 - 255
0 - 255
0 - 255
A: Normal (OFF)
B: Normal/Ceiling (OFF)
C: Hi-Land (ON1/ON2) D: Hi-Land/Ceiling(ON1/ON2)
30-100
30-100
30-100
0-100
0-100
30 - 100
0 - 100
30 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 5
0 - 5
0 - 5
0 - 5
0 - 5
A: Normal (OFF)
B: Normal/Ceiling (OFF)
C: Hi-Land (ON1/ON2) D: Hi-Land/Ceiling(ON1/ON2)
20 - 100
20 - 100
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255