Mechanical Disassembly
c Main, filter boards and lamp removal
1. R emove 2 screws A(M4x6), 2 screws B(T3x8), 2 screws C(M2.5x8) and remove the
main board upward.
2. R emove 2 screws D(M4x6) and 2 screws E(T3x8) and remove the filter shield top.
3. R emove 1 screw F(M3x6) and 2 screws G(T3x8) and remove the filter board upward
off.
4. Loosen 3 screws H and pull the lamp upward off.
Main board
C
Lamp
H
C
B
B
A
A
e
-15-
e
d
d
Filter shield top
F
G
G
Isolation sheet
Filter board
Fig.3