Sanyo PLC-WL2500A Service Manual page 41

Hide thumbs Also See for PLC-WL2500A:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
0 FrameLock Option
2 Field Sense Invert Enable
4 Sub Image Enable
6 Zoom Accelerator Enable
7 DZoom Reset by Keystone
8 Stability Count
9 Sensivity for Signal Lost (HSYNC)
10 Sensivity for Signal Lost (VSYNC)
11 Keystone Filter Signal Center Value
Group 202 Option (MCI)
0 Memory Viewer Please Wait OSD
1 SIMPLE_CHANNEL_NUM
Group 205 Spread Spectrum
0 Ebanle
1 Diviation Freq.
2 Ratio
Group 210 LampContorl
0 DIMMER_CTRL_LEVEL1
1 DIMMER_CTRL_LEVEL2
2 DIMMER_CTRL_LEVEL3
3 DIMMER_CTRL_LEVEL4
4 DIMMER_CTRL_LEVEL5
5 DIMMER_CTRL_LEVEL6
6 DIMMER_CTRL_LEVEL7
7 DIMMER_CTRL_LEVEL8
8 DIMMER_CTRL_LEVEL9
9 DIMMER_CTRL_LEVEL10
10 DIMMER_CTRL_LEVEL11
11 DIMMER_CTRL_LEVEL12
12 DIMMER_CTRL_LEVEL13
13 DIMMER_CTRL_LEVEL14
14 DIMMER_CTRL_LEVEL15
15 DIMMER_AVERAGE_POINT
16 DIMMER_AVERAGE_DATA
17 DIMMER_LEVEL_AUTO
18 DIMMER_LEVEL_NORMAL
19 DIMMER_LEVEL_ECO
20 Panel Life Mode
21 VOLTAGE_LEVEL
22 DIMMER_LEVEL_HIGH
23 Past Calculation System
24 New APL System
25 Red Avarage Level
26 Green Average Level
27 Blue Average Level
28 SAT
29 Chroma Coefficient
Function
Count Value of V-missing
Only used this value for No Signal
Judgement(Hz)
Only used this value for No Signal
Judgement(Line)
0: Off, 1: On
Luminance Level 1 Data for Dimmer: Dim
Level 1 at the less than the Value
Luminance Level 2 Data for Dimmer: Dim
Level 2 at the less than the Value
Luminance Level 3 Data for Dimmer: Dim
Level 3 at the less than the Value
Luminance Level 4 Data for Dimmer: Dim
Level 4 at the less than the Value
Luminance Level 5 Data for Dimmer: Dim
Level 5 at the less than the Value
Luminance Level 6 Data for Dimmer: Dim
Level 6 at the less than the Value
Luminance Level 7 Data for Dimmer: Dim
Level 7 at the less than the Value
Luminance Level 8 Data for Dimmer: Dim
Level 8 at the less than the Value
Luminance Level 9 Data for Dimmer: Dim
Level 9 at the less than the Value
Luminance Level 10 Data for Dimmer: Dim
Level 10 at the less than the Value
Luminance Level 11 Data for Dimmer: Dim
Level 11 at the less than the Value
Luminance Level 12 Data for Dimmer: Dim
Level 12 at the less than the Value
Luminance Level 13 Data for Dimmer: Dim
Level 13 at the less than the Value
Luminance Level 14 Data for Dimmer: Dim
Level 14 at the less than the Value
Luminance Level 15 Data for Dimmer: Dim
Level 15 at the less than the Value
Luminance Data Avarage Point for Mimmer
Luminance Data Avarage Value for Dimmer
Current Dimmer Leverl
Normal Dimmer Level
Eco Dimmer Level
Lamp Voltage
Dimmer Level at High
Initial
1
0
1
0
0
5
350
3
16
1
11
1
80
100
7
14
21
28
35
42
49
56
63
70
77
84
91
98
105
4
-
-
15
0
0
15
-
-
-
-
-
-
160
-41-
Range
Note
0: FrameLockOFF at PC signal
0 - 1
1: FrameLockON at PC signal and 47Hz
(Vfreq) ~ Panel frequency of input signal
Reverse Processing of FLDINVSetting Value
0: Disable - Used FLDINV Setting Value
0 - 1
1: Enable - Used Reversed FLDINV Setting
Value
0:Disable (Service Adjustment Dsiable,
0 - 1
Used all the Center Values
1:Enable (Service Adjustment Enable)
0:Zoom Accelerator OFF,
0 - 1
1:Zoom Accelerator ON
No last memory
0:Enable (Normal), 1:Disable (Dzoo is not
0 - 1
cancelled even if Keystone is cancelled)
No last memory
0 - 255
0 - 32767
0 - 255
0 -30
0 - 1
0 - 11
0 - 1
1 - 500
0 - 300
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
1 - 16
-
* Read only
-
* Read only
0 - 15
0 - 15
0 - 1
Unit: 8bit(Raw Data) * Read only
0 - 15
-
-
-
-
-
-
0 - 255

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-wl2503a

Table of Contents