Mechanical Disassembly
b Optical unit and duct assembly removal
1. Remove 2 screws A(T3x8) to remove the main board holder.
2. R emove 2 screws B(T3x12) and 5 screws C(T3x8) and remove the optical
unit upward off.
3. Remove 9 screws D(T3x8) and remove the duct assembly upward off.
SW901
Lamp cover
switch
T3x12
Panel duct
bottom
FN904
FN903
T3x30 T3x30 T3x12
d
d
d
d
Duct assy
T3x8
Temp sensor A
board
FN902
FN901
T3x30
T3x12
T3x30
C
d
d d
d
d
-17-