Refueling Procedure:
Warning
Diesel fuel and its vapors are dangerous
to your health and the surrounding
environment. Avoid skin contact and/or
inhaling fumes.
1. level tanks — Make sure fuel cells are level with the
ground. Failure to do so will cause fuel to spill from the
tank before reaching full capacity (Figure 28).
caution
alWaYs place trailer on firm level ground before
refueling to prevent spilling and maximize the amount
of fuel that can be pumped into the tank.
Level Ground
Figure 28. Only Fill on Level Ground
NOTICE
onlY use #2 diesel fuel (ultra low sulfur diesel fuel)
when refueling.
2. Remove fuel cap and fill tank as shown in Figure 29.
DIESEL
FUEL
Figure 29. Fueling the Generator
3. never overfill fuel tank — It is important to read the
fuel gauge when filling trailer fuel tank. DO NOT wait
for fuel to rise in filler neck (Figure 30).
dca150ssju4f 60 hz generator• operation manual — rev. #0 (11/0614) — page 29
DO NOT fill on
unlevel ground
=
!
!
Level Ground
FUEL TANK
FILLER PORT
iNspeCtiON/setUp
Figure 30. Full Fuel Tank
caution
do not overfill fuel system. Leave room for fuel
expansion. Fuel expands when heated (Figure 31).
Figure 31. Fuel Expansion
DEF Refueling
Diesel exhaust fluid is an aqueous solution made with 32.5%
high puirty urea (carbamide) and 67.5 deionized water.
DEF is used as a consumable in selective catalytic reduction
(SCR) in order to lower NO
emissions.
1. Remove the filler cap from the DEF tank (Figure 32),
2. Next add DEF fluid to the tank. DO NOT overfill.
D E
F T
A N
K
Figure 32. DEF Tank Filling
concentration from diesel exhaust