Fuser Replacement - Oki ES5460 User Manual

Table of Contents

Advertisement

6.
Turn the two fasteners 90° to the left. This will release the belt from the MFP
chassis.
7.
Pull the lifting bar (6) upwards so that belt tilts up towards the front, and withdraw
the belt unit from the MFP.
8.
Lower the new belt unit into place, with the lifting bar at the front and the drive gear
towards the rear of the MFP. Locate the drive gear into the gear inside the printer by
the rear left corner of the unit, and lower the belt unit flat inside the MFP.
9.
Turn the two fasteners (5) 90° to the right until they lock. This will secure the belt
unit in place.
10.
Replace the four image drums, complete with their toner cartridges, into the printer
in the same sequence as they came out: cyan (nearest the rear), magenta, yellow
and black (nearest the front).
11.
Close the top cover and press down firmly at both sides so that the cover latches
closed.
12.
Gently lower the scanner.
F
USER REPLACEMENT
The fuser is located inside the MFP just behind the four image drum units.
If the MFP has recently been powered on, some fuser components
will be very hot. Handle the fuser with extreme care, holding it only
by its handle, which will only be mildly warm to the touch. A
warning label clearly indicates the area.
Switch off the MFP and allow the fuser to cool for about 10 minutes before opening the
cover.
1.
Gently raise the scanner.
WARNING!
Maintenance > 89

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mc560dn

Table of Contents