Removing Case And Measuring Input Capacitor Voltage - Miller Electric INVISION 456 CC Owner's Manual

Miller electric welding system user manual
Hide thumbs Also See for INVISION 456 CC:
Table of Contents

Advertisement

6-3. Removing Case and Measuring Input Capacitor Voltage

Tools Needed:
5/16 in
!
Significant DC voltage can remain on capac-
itors after unit is Off. Always check the volt-
age as shown to be sure the input capacitors
have discharged before working on unit.
1
1
2
3
+ lead to lower right
terminal, − lead to
upper right terminal
Turn Off welding power source, and
disconnect input power.
1
Outside Handle Screws
To loosen top, remove two outside
handle screws from both handles
and all side bolts.
2
Interconnecting Board PC2
3
Voltmeter
Measure the dc voltage across the
screw terminals on RC3 and RC5
as shown until voltage drops to near
0 (zero) volts.
Proceed with job inside unit. Rein-
stall cover when finished.
802 260 / 801 536
OM-203 034 Page 27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invision 456pXmt 456 cc/cv

Table of Contents