4-7. Stick And MIG Mode Volt-Ampere Curves
A. CC/AC Stick Mode
80
70
60
50
40
30
20
10
0
0
50
B. CC/DC Stick Mode
80
70
60
50
40
30
20
10
0
0
50
C. CV/DC MIG Mode
45
40
35
30
25
20
15
10
5
0
0
100
100
150
200
AC AMPERES
100
150
200
250
DC AMPERES
200
300
400
DC AMPERES
250
300
350
300
350
400
450
500
600
700
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of
other settings fall between the
curves shown.
.
AC output is not available on all
models.