5-8. Selecting Weld Cable Sizes*

Weld Output
Terminals
Y Stop
engine
before
connecting to weld out-
put terminals.
Y Do not use worn, dam-
aged, undersized, or
poorly spliced cables.
This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
*
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
2
( ) = mm
for metric use
***For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.

5-9. Remote Receptacle Information

NOTE
A
A
J
J
K
I
B
B
C L N
H
M
M
D
D
G
G
F
E
*The remaining sockets are not used.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
100 ft (30 m) or Less
10 − 60%
60 − 100%
Welding
Duty
Amperes
Cycle
Cycle
100
4 (20)
150
3 (30)
200
3 (30)
250
2 (35)
300
1 (50)
1/0 (60)
350
1/0 (60)
2/0 (70)
400
1/0 (60)
2/0 (70)
Engine runs at weld/power speed whenever a device connected to the remote
receptacle is running.
24 VOLTS AC
24 VOLTS AC
115 VOLTS AC
115 VOLTS AC
REMOTE
REMOTE
OUTPUT
CONTROL
CONTROL
Not Exceeding***
150 ft
200 ft
(45 m)
(60 m)
Duty
4 (20)
4 (20)
3 (30)
3 (30)
2 (35)
1 (50)
2 (35)
1 (50)
1/0 (60)
1 (50)
1/0 (60)
2/0 (70)
2/0 (70)
3/0 (95)
3/0 (95)
4/0 (120)
3/0 (95)
4/0 (120)
Socket*
A
24 volts ac.
B
Contact closure to A completes 24 volt ac contac-
tor control circuit and keeps engine at Run speed
in all modes. Protected by circuit breaker CB5.
I
115 volts ac. Protected by fuse F2.
J
Contact closure to I completes 115 volts ac
contactor control circuit.
C
0 to +10 volts dc output to remote control in Stick
and TIG modes. +10 volts dc output to remote
control in Wire mode.
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from
remote control. Voltage is dependent on front pan-
el Voltage/Amperage control setting.
G
Circuit common for 24 and 115 volts ac circuits.
GND
GND
K
Chassis common.
250 ft
300 ft
350 ft
(70 m)
(90 m)
(105 m)
10 − 100% Duty Cycle
2 (35)
1 (50)
1/0 (60)
1/0 (60)
2/0 (70)
3/0 (95)
2/0 (70)
3/0 (95)
4/0 (120) 4/0 (120)
2 ea. 2/0
3/0 (95)
4/0 (120)
(2x70)
2 ea. 2/0
2 ea. 3/0
4/0 (120)
(2x70)
(2x95)
2 ea. 2/0
2 ea. 3/0
2 ea. 3/0
(2x70)
(2x95)
(2x95)
2 ea. 2/0
2 ea. 3/0
2 ea. 4/0
(2x70)
(2x95)
(2x120)
Socket Information
OM-4407 Page 21
400 ft
(120 m)
1/0 (60)
3/0 (95)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
2 ea. 4/0
(2x120)
S-0007-F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trailblazer dcTrailblazer 301 g

Table of Contents