Mechanism Troubleshooting Guide; Deck Mechanism - Zenith ABV341 Series Service Manual

Table of Contents

Advertisement

MECHANISM TROUBLESHOOTING GUIDE

1.Deck Mechanism

A.
Auto REW doesn't work.
YES
Is the supply to the END sensor
END sensor "H"?
"H": more than 3.5V
"L": less than 0.7V~1V
YES
Is the voltage across IR LED
between 0.8~1.5V?
NO
Check syscon circuit.
B.
No F/R modes.
YES
Is the present mode,
F/R Mode?
YES
Does the Capstan Motor rotate?
YES
Does the T/Up, Supply Reel
rotate?
YES
Check syscon circuit.
NO
Is the Vcc. voltage of End
sensor 5V?
YES
Replace End sensor.
NO
Replace LED.
NO
Is the mode SW assembled
correctly (refer to Pages 4-14.)
NO
Is the normal voltage supplied to
the Capstan Motor Vcc1, Vcc2.?
YES
Is terminal voltage (Vctl) of Capstan
Motor supply side more than 4V?
YES
Replace the Capstan Motor.
4-23
NO
Check the syscon power.
NO
Check Servo, Power Circuits.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xbv343 seriesXbv342 series

Table of Contents