2-1. Specifications

Rated
Rated
Model
Welding
Output
250 A @ 35
250 Amp
Volts DC, 100%
Duty Cycle
300 A @ 32
300 Amp
Volts DC, 100%
Duty Cycle
*While idling

2-2. Duty Cycle And Overheating

Overheating
SECTION 2 − INSTALLATION
Open-
Amperes Input at Rated Load Output, 50 or 60 Hz, Three-Phase
Circuit
Circuit
Voltage
200
220
Range
V
V
DC
34.5
14−44
−−
1.7*
38
34.5
14−44
3*
2.8*
CP302
CP252TS
0
Minutes
230
380
400
440
V
V
V
V
30
−−
−−
−−
1.4*
33
20
19
17.3
2.7*
1.9*
1.6*
1.5*
100% Duty Cycle
Continuous Welding
15
OR
Reduce Duty Cycle
460
520
575
KVA
V
V
V
15
11.9
−−
−−
0.7*
0.57*
16.5
14.6
13.0
13.1
1.4*
1.1*
0.7*
0.97*
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before welding.
Y Exceeding duty cycle can
damage
unit
and
warranty.
A/V
duty1 4/95 / Ref. SA-177 714-B
OM-259 Page 9
KW
11.2
0.42*
12.3
0.68*