5-9. Process Set Up Push Button

3
Press the Process Set Up push button the
first time will illuminate the button LED and
Process LED above the button. Both
displays will show the current process and,
if desired, these displays will be active to
allow selecting a new process. Default
processes are MIG, PULSE, and ACCU
PULSE.
Pressing the Process Set Up push button a
second time will illuminate the Wire Type
LED and the bottom display will show wire
types available for the selected process. To
make a selection, rotate the Adjust control.
Pressing the Process Set Up push button a
third time will keep Wire Type LED lit, but the
upper display will be active and show wire
sizes available for the current wire type. To
Wire Description
Wire Abbreviation
Steel
Stainless Steel
Cored Tubular Wire
Aluminum
* Not all wire types may be available with your unit.
OM-228 956 Page 24
Process
Wire Type
Gas Type
Process Set Up
make a selection, rotate the Adjust control.
Pressing the Process Set Up push button a
fourth time will illuminate the Gas Type LED
and both displays will show available gas
selections for the process, and wire type
and wire size selection. To select an item,
rotate the Adjust control.
Pressing the Process Set Up push button a
fifth time will load the program that matches
the selected parameters (process, wire
type, wire size, gas). The upper display will
show PROG and the lower display will show
LOAD.
If no changes were made to any setup items,
no program will be loaded, and unit will return
to standby mode.
Table 5-1. Welding Wire And Gas Abbreviations*
Alloy Type
STL
E70, E100, E120
SS
308, 309, 312, 316
MCOR
71, 76, 86R, 409,
439
439
ALUM
4XXX, 5XXX
2
1
If a custom program is loaded using an
optional PDA with File Management software,
the upper display will show CUST and the
lower display will show PROG. The Adjust
control remains active to allow loading a
standard program in place of the custom
program.
Pressing and holding the Process Set Up
push button in on power up allows viewing
the software revisions of each circuit board
in the system. The top display shows the
board (PCM, UIM, WFCM, and AIM (auto-
mated units only) and the lower display
shows the last 3 digits of the circuit board
part number plus a letter designator. Press
the flashing Feeder Set Up push button to
exit the screen displays and continue the
power up process.
Gas Type
100% CO
90% Argon/10% CO
85% Argon/15% CO
75% Argon/25% CO
95% Argon/5% CO
95% Argon /5% O
98% Argon/2% O
98% Argon, 2% O
(81Ar/18HE/1CO
Accu-pulse)
90HE/7-1/2Ar/2-1/2CO
MIG/RMD/Accu-pulse)
90% Argon/10% CO
98% Argon/2% O
100% Argon
1
Process Set Up Push Button
2
Process Set Up LED
3
Program Selection LEDs
Gas Abbreviation
,
CO2
2
,
C10
2
,
C15
2
,
C25
2
,
C5
2
,
OX5
2
OX2
2
OX2
2
Tri Gas
2
Tri Gas
2
C10
2
OX2
2
ARGN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Axcess alumafeed 75