Superior WRE3836WS Installation And Operation Instructions Manual page 8

Wood-burning outdoor fireplace
Table of Contents

Advertisement

Secure to Collars with Metal Tape, Screws
or Straps (Min. of 1/4" x 20" in size)
Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)
Figure 6 - Outside Air Kit
WARNING: The opening in
collar around chimney at top of
fireplace must not be obstructed.
Never use blown insulation to fill
chimney enclosure.
ASSEMBLY AND INSTALLATION OF
DOUBLE WALL CHIMNEY SYSTEM
Each double wall chimney section consists of
a galvanized outer pipe, a stainless steel in-
ner flue pipe and a wire spacer. Pipe sections
must be assembled independently as chimney
is installed. When connecting chimney directly
to fireplace, inner flue pipe section must be
installed first with lanced side up. Outer pipe
section can then be installed over flue pipe
section with hemmed end up. Press down
on each pipe section until lances securely
engage hem on fireplace starter. The wire
will assure proper spacing between inner and
outer pipe sections.
Note: For Canada, use chimney parts desig-
nated HT.
Opening in collar around
chimney at top of fireplace must
not be obstructed. Never use
blown insulation to fill chimney
enclosure.
8
VENTING INSTALLATION
Air Inlet
Location
Must Allow
For Bushes
or Snow
Air Inlet
Eyebrow
Vent Hood
Required for
Wall Installation
www.SuperiorFireplaces.US.com
Continued
12
/
"
3
8
Galvanized
Outer Pipe
8" Stainless
Inner Pipe
PART NO.
36"
12-8DM
12-8HT
18-8DM
18-8HT
24-8DM
24-8HT
36-8DM
36-8HT
48-8DM
48-8HT
RT-8DM
RTL-8DM
RLT-8DM
RTT-8DM
RTTL-8DM
RLTT-8DM
ET-8DM
ETO-8DM
ETL-8DM
ETLO-8DM
* The lineal gain for the terminations is
measured to the flue gas outlet height.
LINEAL GAIN
DESCRIPTION
Fireplace
Pipe Section
Pipe Section
Pipe Section
Pipe Section
Pipe Section
Round Termination
Round Termination
Round Termination
Round Termination
with Slip Section
Round Termination
with Slip Section
Round Termination
with Slip Section
Square Chase-Top
Square Chase-Top
with Mesh
Square Chase-Top
with Slip Section
Square Chase-Top
with Mesh & Slip
Section
Figure 7 - Lineal Gain
Hemmed
End
GAIN
37
/
"
1
2
10
/
"
5
8
16
/
"
5
8
23
/
"
5
8
34
/
"
5
8
46
/
"
5
8
6
/
"*
7
8
7
/
"*
3
4
7
/
"
1
2
6
/
" to
7
8
23
/
"*
1
8
8
/
" to
1
2
21
/
"*
1
2
7
/
" to
1
2
21
/
"*
1
4
12"*
12"*
7" to 15"*
12" to
25
/
"*
1
2
127023-01A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wre3836whWre3836rhWre3836rs