7.10. Pump
Unhook the pump
from the supports.
7.11. Flow-meter
Lift the fl ow meter out of the casing assembly and remove the electrical
and water circuit connections.
7.12. Boiler
Unscrew the screw shown at
unthread the support boiler
A
D
Disconnect the water circuit connections (A) and
electrical connections (B), loosen the safety valve (C) and
slide the pump off the brackets (D).
Unscrew the screw shown
electrical and water circuit connections.
C
B
D
A
A
B
B
and remove the
07 DISASSEMBLY
Pag. 7/9