Gaggia Anima Service Manual page 35

Table of Contents

Advertisement

GAGGIA ANIMA
Page 3 (BU)
Page 3 (BU)
Insert the BrewUnit
Insert the BrewUnit
The indications BU-P
The indications
BU-P changes from "N" to "Y".
Note: removing the BrewUnit the indication from "Y" to "N" requires
Note:
removing the BrewUnit the indication from "Y" to "N" requires
about 2-3 seconds to switch.
about 2-3 seconds to switch.
ERROR: Check the BU presence Microswitch and the wiring (JP16).
Close the Door and Dreg Drawer
Close the Door and Dreg Drawer
The indication
The indication DOOR
DOOR change from "N" to "Y"
ERROR: The indication DOOR does not change; check
the Microswitch for the door and the wiring (JP14).
Note: without the Dreg Drawer correctly inserted the DOOR indica-
tion cannot change!
Press
Press Z7
Z7 " "
" to move to the next screen
" to move to the next screen
The machine passes to the Page 3
The machine passes to the Page 3 (BU PAGE)
Start condition
Start condition
Press the Z1 button to move the BU to Work
Press the Z1 button to move the BU to Work
IMPORTANT NOTE: If the DREGDRAWER is not inserted or the
DOOR is not closed the BU test cannot be performed. If these 2
inputs are not in the right position, a warning message will be
shown and the display turns to red.
When the BU reaches the work position the indication
When the BU reaches the work position the indication WORK
es from "N" to "Y", the number of the current is less than 200mA
es from "N" to "Y", the number of the current is less than 200mA
(without BU) or 300mA (with BU).
(without BU) or 300mA (with BU).
ERROR: The indication
ERROR:
The indication WORK
the display backlight changes from white to red; Check the work
the display backlight changes from white to red; Check the work
microswitch (broken?), the BU motor (blocked?) and the wiring
microswitch (broken?), the BU motor (blocked?) and the wiring
(JP16).
(JP16).
ERROR:
ERROR: ( ( Without BU
Without BU) The absorbed current is more than
200mA, the display backlight changes from white to red; check the
200mA, the display backlight changes from white to red; check the
BU and the motor.
BU and the motor.
changes from "N" to "Y".
change from "N" to "Y"
(BU PAGE)
WORK doesn't change and remain "N",
doesn't change and remain "N",
) The absorbed current is more than
05 TROUBLESHOOTING
WORK chang-
chang-
Pag. 4/9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Anima xl