Gaggia Anima Service Manual page 39

Table of Contents

Advertisement

GAGGIA ANIMA
When the Steam-Out is complete the following parameters are reset to their default values:
Length "Espresso" product
Length "Espresso Lungo" product
Length "Cappuccino" (Coffee + Milk product)
Length "Milk" product
Stand-By Time
Count Coffee
The request for Priming the Circuit at the fi rst switch on is set.
Brewing Unit Empty
Aroma Strength
BU current array (BU during rinsing)
Grinder Sensing Array
Grinding time Aroma Very Light (1 Bean)
Grinding time Aroma Light/Medium (2/3 Beans)
Grinding time Aroma Strong/Extra Strong
(4/5 Beans)
Filter Presence
Filter Pulses
Last Error Log
Coffee Duct Empty = TRUE (To grind more fi rst time after steam-out and refi ll duct with coffee)
IMPORTANT NOTE: to execute the Steam-Out procedure the
DREGDRAWER must be in place and the DOOR must be closed.
If these 2 conditions are not respected a warning message is shown
on the display and the Steam-Out is interrupted.
The machine starts the Steam Out and in the display appears the
indication "ON".
While the Steam Out runs the Electro valve is opened and water
comes out the Water/Steam pipe.
When the Steam Out is complete the message "COMPLETE" is
shown on the Display.The Electro valves automatically closes and the
machine can be switched off.
05 TROUBLESHOOTING
(Default 145 impulses)
(Default 345 impulses)
(Default 170 impulses coffee & 34sec milk)
(Default 34 seconds)
(Default 15 minutes)
(Default 0)
(Default 3 beans)
(Default 150mA)
Default 2000ms)
(Default 3000ms)
(Default 3500ms)
(Default 4000ms)
(Default OFF)
(Default 0)
(Default 0)
Pag. 8/9