MAINTENANCE SCHEDULE

Annually (Before the onset of the Burning Season)
MAINTENANCE TASK
Inspecting/Cleaning Burner, Logs
and Controls
Check Flame Patterns and Flame Height
Inspecting/Cleaning Pilot and Burner
Checking Vent System
Appliance Checkout
Replacing Rockwool Ember Materials
Periodically (After the Burning Season)
MAINTENANCE TASK
Cleaning Firebox Interior
Check Flame Patterns and Flame Height
Checking Vent System
Cleaning Front Glass Enclosure Panel
58
ACCOMPLISHING PERSON
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Service
Technician
ACCOMPLISHING PERSON
Homeowner
Homeowner
Homeowner
Homeowner
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
PROCEDURE
Inspect valve and ensure it is properly operating. Check piping
for leaks. Vacuum the control compartment, fireplace logs and
burner area.
Refer to Figure 9 on Page 13 and verify the flame pattern and
height displayed by the appliance conforms to the picture. Flames
must not impinge on the logs. Ensure flames are steady (not
lifting or floating).
Refer to Figures 11 and 12 on Page 14. Remove any surface
build-up on pilot and burner assembly. Wipe the pilot nozzles,
igniter/flame rod and hood. Ensure the pilot flame engulfs the
flame sensor as shown.
Inspect the vent system at the top and at the base (within the
firebox) for signs of blockage or obstruction. Look for any signs
of dislocation or deterioration of the vent components. Note:
Excessive condensation can cause corrosion of caps, pipe &
fittings (excessive condensation can be caused by long lateral
runs, too many elbows and/or exterior portions of the system
being exposed to cold weather). Also inspect wall straps or
plumbers's tape to ensure it is secure and in place.
Perform the appropriate appliance checkout procedure detailed
in this manual.
Remove old ember materials (rockwool) and vacuum the rockwool
placement area. Place new embers as described in this document.
PROCEDURE
Carefully remove logs, rockwool, volcanic stone and vermiculite.
Vacuum out interior of the firebox. Clean firebox walls and log
grate. Replace logs, Rockwool and vermiculite as detailed in
this manual.
Refer to Figure 9 on Page 13 and verify the flame pattern and
height displayed by the appliance conforms to the picture. Flames
must not impinge on the logs.
Inspect the vent system at the top and at the base (within the
firebox) for signs of blockage or obstruction. Look for any signs
of dislocation of the vent components.
Clean as necessary following the directions provided in this
manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS
WHILE HOT.
Installation and Operation Instructions
900299-00, 08/2015

Advertisement