Maintenance Schedule - Superior 500 Series Homeowner's Care And Operation Instructions Manual

Direct-vent
Hide thumbs Also See for 500 Series:
Table of Contents

Advertisement

Maintenance Schedule

Annually (Before the onset of the Burning Season)
Maintenance Task
Inspecting/Cleaning Burner, Logs
and Controls
Check Flame Patterns and Flame Height
Inspecting/Cleaning Pilot and Burner
Checking Vent System
Appliance Checkout
Replacing Rockwool Ember Materials
Periodically (After the Burning Season)
Maintenance Task
Cleaning Firebox Interior
Check Flame Patterns and Flame Height
Checking Vent System
Cleaning Front Glass Enclosure Panel
Accomplishing Person
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Services Technician
Accomplishing Person
Homeowner
Homeowner
Homeowner
Homeowner
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Procedure
Inspect valve and ensure it is properly operating.
Check piping for leaks. Vacuum the control
compartment, fireplace logs and burner area.
Refer to Figure 7 (D, DT, DR-500), 8 (D,
DT,DR-600) or 9 (D,DT,DR-800) on page 7
and verify the flame pattern and height displayed
by the appliance conforms to the picture. Flames
must not impinge on the logs.
Refer to Figure 10 (SIT Millivolt), Figure
11 (Honeywell Millivolt) or Figure 12 (Elec-
tronic) on page 8 . Remove any surface
build-up on pilot and burner assembly. Wipe
the pilot nozzles, ignitor/flame rod and hood.
Ensure the pilot flame engulfs the flame
sensor as shown.
Inspect the vent system at the top and at the
base (within the firebox) for signs of blockage
or obstruction. Look for any signs of disloca-
tion of the vent components.
Perform the appropriate appliance checkout
procedure detailed in this manual.
Remove old ember materials and vacuum the
screened rockwool placement area. Place new
rockwool as described in this document.
Procedure
Carefully remove logs, Rockwool and volca-
nic stone if used. Vacuum out interior of the
firebox. Clean firebox walls and log grate.
Replace logs, Rockwool and volcanic stone
as detailed in this manual.
Refer to Figure 7 (D, DT, DR-500), 8 (D,
DT,DR-600) or 9 (D,DT,DR-800) on page 7
and verify the flame pattern and height dis-
played by the appliance conforms to the picture.
Flames must not impinge on the logs.
Inspect the vent system at the top and at the
base (within the firebox) for signs of block-
age or obstruction. Look for any signs of
dislocation of the vent components.
Clean as necessary following the directions
provided in this manual. DO NOT TOUCH OR
ATTEMPT TO CLEAN GLASS WHILE HOT.
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents