Section 5
The Utility section of the 260 DriveRack gives you the ability to perform several key operational
functions to the DriveRack including: Security settings, Power-up features, Program list organi-
zation, Auto EQ plotting, adjustment of Output Jumper settings and Display contrast settings.
Additionally, pressing and holding the utility button will allow you to enter the metering sec-
tion of the 260. This section lets you monitor aspects of the unit including: Compression,
Limiting, Zone Controller levels and Output trim. Use this section of the manual to make your-
self familiar with all aspects of the Utility menu of the DriveRack system.
5.1.1 -Page 1 - LCD Contrast / Auto EQ Plot
Page 1 of the Utility menu offers LCD contrast control and Auto EQ Plot selection. Since venues
and applications vary, the 260 DriveRack provide you with the option of changing the contrast
of the custom display. To make any adjustments to the display contrast, press the UTILITY
button and the page will appear as follows:
• Select the Contrast adjustment by pressing the DATA wheel until the con-
trast percentage is selected. Once the contrast has been selected, proceed
to rotate the DATA wheel until the desired contrast has been established.
Contrast adjust ranges from 01 to 16.
• Select the RTA or GEQ for the Auto EQ plot press the DATA wheel until the
Auto EQ Plot is selected. Once the desired option has been selected, pro-
ceed to rotate the DATA wheel select either RTA or GEQ. To exit, press
the PROGRAM/CONFIG button.
5.1.2 -Page 2 - PUP Program/Mute
The Utility menu of the 260 DriveRack also offers the option of setting the PUP (Power Up)
Program option of either Current or Stored and PUP Mutes, which allows to you power up with
all outputs either muted or at the last setting prior to powering down. The following explains
the difference between Load On and Load OFF settings. To access and edit the Load Stored
option of the unit, use the following procedure.
• From Program mode, press the UTILITY button and use the PREV PG and NEXT PG but-
ton to move to the page that appears as follows:
Stored: After cycling the power (or power failure), the unit will automatically load a program
from the program table. No unstored edits will be saved.
40
DriveRack™ User Manual
Utilities/Meters
Utility
LCD Contrast
Auto EQ Plot
Power Up Modes
PUP Program
PUP Mute
DriveRack
10
RTA
Stored
Current
®
®