Failure - Metrologic StratosS MS2220 Installation And User Manual

Scanner / avery scale
Hide thumbs Also See for StratosS MS2220:
Table of Contents

Advertisement

S
O
CANNER
PERATION
I
D
NDICATOR
ESCRIPTIONS
Failure Modes
Flashing Blue and One Razzberry Tone
This indicates that the scanner has experienced a laser subsystem failure. The scanner will try up to 3 times to correct the
failure condition. If the laser subsystem continues to fail, that subsystem (horizontal or vertical) will be shut down and an
error indication will be shown on the Diagnostic Indicator Display. This error stays on the display until corrected. If the
remaining subsystem is still operational, scanning will continue using the operational components.
Flashing Blue and White and Two Razzberry Tones
This indicates that the scanner has experienced a motor subsystem failure. The scanner will try up to 3 times to correct the
failure condition. If the motor subsystem continues to fail, that subsystem (horizontal or vertical) will be shut down and an
error indication will be shown on the Diagnostic Indicator Display. This error stays on the display until corrected. If the
remaining subsystem is still operational, scanning will continue using the still operational components.
Continuous Razzberry Tone with Both LEDs Off
If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an electronic failure. Return the unit
for repair at an authorized service center.
Three Beeps - On Power Up
If the scanner beeps 3 times on power up then, the nonvolatile memory that holds the scanner configuration has failed.
Return the unit for repair at an authorized service center.
34

Advertisement

Table of Contents
loading

Table of Contents