  • Page 1 METROLOGIC INSTRUMENTS, INC. IS4225 ScanGlove ® Laser Bar Code Scanner Installation and User’s Guide...
  • Page 2 Copyright © 2007 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976.
  • Page 3: Table Of Contents

    ABLE OF ONTENTS Introduction... 1 Scanner and Accessories... 1 Scanner Installation ... 2 Scanner Configuration to the Host System... 3 Parts of the Scanner... 4 Visual Indicators ... 5 Audible Indicators ... 9 Labels... 10 Maintenance... 11 Infrared (IR) Object Sensor ... 12 Scan Field ...
  • Page 5: Introduction

    NTRODUCTION The IS4225 ScanGlove The ScanGlove is designed to be used as a “hands-free” wearable scanner or a stationary desktop scanner. Every ScanGlove is equipped with ScanQuest that allows the scanner to read bar codes automatically as the operator presents the bar code to the scanner.
  • Page 6: Scanner Installation

    See power source caution statement on page 10 of this manual. To maintain compliance with federal regulations 21 CFR, Part 1040.10, section (f)(6) the scanner must be plugged into an electrical outlet with a switch accessible to the user or be powered by a host system containing a...
  • Page 7: Scanner Configuration To The Host System

    The IS4225 is shipped from the factory pre-configured to a set of default parameters. It may be necessary to change the default parameters to match the host system’s requirements or to enable additional scanner functions. For a list of possible parameter settings, refer to the Default Settings section of this guide.
  • Page 8: Parts Of The Scanner

    If a specified time has elapsed without any scanning, the unit will enter a “standby” mode. To reactivate the unit, place an object in front of the IR sensor. The red LED will turn on when the scanner is ready to scan.
  • Page 9: Visual Indicators

    ISUAL NDICATORS There is a red and a green LED located on the top of the scanner. When the scanner is on, the flashing or constant, illumination of the LEDs indicates the status of the current scan and the scanner.
  • Page 10 IGNAUX PTIQUES Sur la partie supérieure du scanner se trouvent une diode LED rouge et une diode LED verte. Quand le scanner est sous tension, les diodes rouge et verte clignotantes ou allumées vous informent sur l'état de palpage et de scanner.
  • Page 11 PTISCHE NZEIGEN Auf der Oberseite des Scanners befinden sich eine rote und eine grüne Leuchtdiodenanzeige. Ist der Scanner eingeschaltet, so geben Ihnen die blinkenden oder feststehenden Leuchtdiodenanzeigen Aufschluß über den Abtast und Scannerstatus. Es gibt zwei mögliche Gründe, weshalb die Leuchtdiodenan Weder rote zeigen nicht aufleuchten.
  • Page 12 EGNALI TTICI Sulla parte superiore dello scanner si trovano due diodi luminosi: uno rosso e uno verde. Quando lo scanner è inserito, i diodi luminosi, che possono o essere accesi in continuazione o lampeggiare, Vi informano sullo stato della scansione e dell’apparecchio.
  • Page 13: Audible Indicators

    UDIBLE NDICATORS The scanner provides sounds to signal certain conditions. To change the volume (four settings are available) or turn the beeper off, refer to Scanner Operation: Beeper Options in the MetroSelect Single-Line Configuration Guide ( 02544). One Beep Razzberry Tone...
  • Page 14: Labels

    * Labels not shown to scale. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA-C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC 60950-1, the power source should meet applicable performance requirements for a limited power source.
  • Page 15: Maintenance

    AINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. Gently wipe the output window.
  • Page 16: Infrared (Ir) Object Sensor

    LED will flash. When the laser decodes a bar code, the scanner transmits the data to the host system and emits a beep to show that decoding is complete. The IR sensor range is configurable for two ranges.
  • Page 17: Scan Field

    Scan Field The depth of field for the scanner is 12.7 mm to 203 mm (.5" to 8") from the face of the output window for .33 mm (13 mil) Bar Codes. Figure 3. Scan Field for .33 mm (13 mil) Bar Codes...
  • Page 18: Specifications

    PECIFICATIONS PERATIONAL Light Source: Depth of Field: Width of Scan Field: Scan Speed: Scan Pattern: Min Bar Width: Decode Capability: System Interfaces: Print Contrast: Number of Characters Read: Roll, Pitch, Yaw: Beeper Operation: Indicators (LED): ECHANICAL Length x Width x Height: Weight: Cable Termination: LECTRICAL...
  • Page 19: Default Settings

    Many functions of the scanner can be "configured", that is enabled or disabled. The scanner is shipped from the factory configured to a set of default conditions. All factory default parameters have an asterisk ( * ) in the default column of the charts on the following pages .
  • Page 20 EFAULT ETTINGS ARAMETER ACK/NAK XON/XOFF No Intercharacter Delay 1 Millisecond Intercharacter Delay 5 Millisecond Intercharacter Delay 10 Millisecond Intercharacter Delay 25 Millisecond Intercharacter Delay 100 Millisecond Intercharacter Delay DTR Input DTR Scan Disable “DE” Disable Command LRC Calc+ Transmit RS232 Start LRC on first RS232 Byte Start LRC on Second RS232 Byte Carriage Return...
  • Page 21 EFAULT ETTINGS ARAMETER RSS Limited ID “]e0” RSS Limited App ID “01” RSS Limited Check Digit Full ASCII code 39 Code 39 Codabar Code 128 Code 93 Interleaved 2 of 5 (ITF) Code 11 Hong Kong Matrix 2 of 5 Airline 2 of 5 Minimum 1 Character Code Length Minimum 3 Character Code Length...
  • Page 22 UK Plessey Special Format A to X conversion (UK) Scan Count Test Mode Scanability Test Mode Normal Scan/Operating Test Mode Transmit Scanner Parameters Test Mode Code ID Sanyo 635 ECR Protocol Post Software ID Characters “Newcode” Mode A “Newcode” Mode B...
  • Page 23 EFAULT ETTINGS ARAMETER BIO DATA Mode Golden Bountiful Formatting Intermec Polling Mode D (limited function) Enable Sineko Mode Enable Caps Lock Mode (for MI951 keyboard wedge) Enable French Wyse 120 PC Term Rochford Tompson Mode RTS Counter Toggle Beep on BEL RS232 Bancorner Mode FedEX parsing Retransmit of Same Code...
  • Page 24 EFAULT ETTINGS ARAMETER Alt Mode Auto Detection or Caps Lock User-Defined Caps Lock F0H Break Code Transmission 800 Microsecond Delay-Enter Scan Code 15 Millisecond Delay-Enter Scan Code 7-5 Millisecond Delay-Enter Scan Code IGHT RS232 EFAULT EYBOARD EDGE...
  • Page 25: Troubleshooting Guide

    The IS4225 requests 100mA from the USB port. If the USB port cannot supply this, a notification window will appear on the screen. Re-configure the scanner using the appropriate codes for your scanner model.
  • Page 26: Regulatory Compliance

    Non guardate mai il raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l’apparecchio. Facendolo potete esporVi ad una esposizione laser rischiosa.
  • Page 27 Class A Devices The following is applicable when the scanner cable is greater in length than 3 meters (9.8 feet) when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner dépassant 3 métres (9.8 pieds) de long en extension maximale:...
  • Page 28 Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner ne dépassant pas 3 métres (9.8 pieds) de long en extension maximale:...
  • Page 29: Patents

    ATENTS This METROLOGIC product may be covered by, but not limited to, one or more of the following U.S. Patents: U.S. Patent No. 5,260,553; 5,340,971; 5,340,973; 5,424,525; 5,468,951; 5,484,992; 5,525,789; 5,528,024; 5,627,359; 5,661,292; 5,742,043; 5,756,982; 5,777,315; 5,789,730; 5,789,731; 5,825,012; 5,874,721; 5,886,337;...
  • Page 30: Limited Warranty

    METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. METROLOGIC RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN. ORPORATE EADQUARTERS ORTH MERICA Metrologic Instruments, Inc. 90 Coles Rd. Blackwood, NJ 08012-4683 Customer Service Department Tel: 1-800-ID-METRO Fax: 856-228-6673 Email: info@metrologic.com...
  • Page 31: Index

    NDEX application ...1 audible...5–9 autodiscriminates...14 bar code ... 4, 5–9, 11, 12, 21 beep ... 5–9, 14, 15, 21 cable...1, 4, 14 caution...10, 22 CDRH ...10, 14 class ...24 communication ... 1, 4, 5–9, 15–20 compliance ...22, 23 configuration guide ...1, 9 contrast...14 current ...14 customer service ...1...
  • Page 32 NDEX razzberry tone ...9, 15 red LED ...4, 5–9 rights...25 roll, pitch, yaw...14 RS232 ... 14, 15–20 safety...22, 24 scan field ... 5–9, 12, 13 scan pattern...14 scan speed ...1, 14 serial number...10 shock ...14 short range activation ... 1, 12, 15 software...21 specifications...4, 14 stand...1, 14...
  • Page 36 May 2007 Printed in the USA 0 0 - 0 2 2 5 8 C...

Table of Contents