ABLE OF ONTENTS NTRODUCTION Product Overview ..................... 1 Key Product Features..................1 Applications and Protocols ................2 Scanner and Accessories................. 3 Design Specifications ..................6 ODEL HARACTERISTICS IS1650 Scanner....................8 Components....................8 Dimensions ....................9 Caution and Serial Labels ................10 NSTALLATION The PowerLink Cable ..................
Page 4
ABLE OF ONTENTS Visual Indicators ..................... 23 Failure Modes....................24 Depth of Field by Minimum Bar Code Element Width ........25 IR Activation Range..................26 AINTENANCE Daily Maintenance..................27 ROUBLESHOOTING UIDE Troubleshooting Symptom / Solution Chart ............ 28 EFAULT ETTINGS Communication Parameters ................
NTRODUCTION RODUCT VERVIEW The IS1650 is a high performance area imaging bar code scanner that utilizes a high-resolution CMOS imaging sensor for unrivaled image quality. The IS1650 is the choice of 2D imaging scanners that delivers superior performance for presentation and fixed-mount applications. The IS1650 employs Omniplanar, Inc.’s SwiftDecoder™...
NTRODUCTION PPLICATIONS AND ROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. ERSION CANNER OMMUNICATION ROTOCOL DENTIFIER RS232 (TX, RX, RTS, CTS, DTR) Low Speed USB and RS232 Transmit/Receive IS1650 - Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive IBM 46xx, Full Speed USB, and RS232 Transmit/Receive...
NTRODUCTION CANNER AND CCESSORIES ASIC Part # Description IS1650 Area Imaging Bar Code Scanner ® 00-02544 MetroSelect Single-Line Configuration Guide* 00-02281 Area Imaging Supplemental Configuration Guide* IS1650 Series Area Imaging Bar Code Scanner 00-02287 Installation and User’s Guide* Also available for download on the Metrologic website - www.metrologic.com PTIONAL CCESSORIES Part #...
Page 8
NTRODUCTION CANNER AND CCESSORIES PTIONAL CCESSORIES Part # Description IS1650 Scanner Interface Specific Cables RS232 PowerLink Cable with Built in Power Jack 59-59000-3 2.2 m (7.3 ft.) straight, black Keyboard Wedge PowerLink Cable with Adapter Cable 59-59002-3 2.2 m (7.3 ft.) straight, black Stand Alone Keyboard PowerLink Cable 59-59020-3 2.2 m (7.3 ft.) straight, black...
Page 9
NTRODUCTION CANNER AND CCESSORIES PTIONAL CCESSORIES Part # Description 00-02001 IS1650 Series Stand Installation Guide 46-00710 Flex Stand, Kit Flex Stand, Kit Components a. Stand Base ................Qty. 1 b. Flexible Shaft................Qty. 1 c Flexible Shaft Cover ..............Qty. 1 d. Scanner Cradle.................Qty. 1 e.
NTRODUCTION ESIGN PECIFICATIONS IS1650 D ESIGN PECIFICATIONS PERATIONAL Light Source: LED 645 nm Pulse Duration: 1 ms to 8 ms Maximum Output Maximum 85 mA emits 3,120 mlm of an Osram LED: 0 mm – 254 mm (0" – 10") for Depth of Scan Field: 0.330 mm (13 mil) Bar Code at Default Setting 49 mm W x 19 mm H (1.9”...
Page 11
NTRODUCTION ESIGN PECIFICATIONS IS1650 D ESIGN PECIFICATIONS LECTRICAL Input Voltage: 5.0VDC ± 0.25V Peak = 2 W (Typical) Operating = 1.65 W (Typical) Power: Idle / Standby = 800 mW (Typical) Peak = 400 mA (Typical) Current: Operation = 330 mA (Typical) Idle / Standby = 160 mA (Typical) DC Transformer: Class 2;...
ODEL HARACTERISTICS IS1650 S CANNER Components Figure 1. Scanner Components Item Description Red Window LED Aperture Blue LED See Visual Indicators (on page 23) White LED See Visual Indicators (on page 23) Yellow LED See Visual Indicators (on page 23) Trigger Initiates Bar Code Read Speaker...
ODEL HARACTERISTICS IS1650 S CANNER Dimensions Figure 2. Scanner Dimensions Figure 3. M3 Mounting Hole Dimensions Caution: The depth of each mounting hole is 12 mm (0.5”). For fixed mount, the mounting screws should not be over-tightened or go deeper than 10 mm (0.4”) passing the bottom surface of the unit.
ODEL HARACTERISTICS IS1650 S CANNER Caution and Serial Number Labels Each scanner has a label located on the bottom of the unit, as well as text embedded into the bottom casing. This label provides the unit’s model number, date of manufacture, serial number, CE and caution information. The following figure gives an example of the label/text and their location.
NSTALLATION OWER ABLE Connecting Important: If the PowerLink cable is not fully ‘latched’, the unit can power intermittently. Figure 5. Figure 6. Disconnecting Before removing the cable from the scanner, Metrologic recommends that the power on the host system is off and the power supply has been disconnected from the PowerLink cable.
NSTALLATION ABLE NSTALLATION NTERFACE PECIFIC RS232 IS1650-14 Turn off the host device. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS1650. There will be an audible click when the connector lock engages. Connect the 9-pin D-type connector of the communication cable to the proper COM port of the host device.
NSTALLATION ABLE NSTALLATION NTERFACE PECIFIC Keyboard Wedge IS1650-47 Turn off the host device. Plug the 10-pin RJ45 male end of the PowerLink cable into 10-pin socket on the IS1650. There will be an audible click when the connector lock engages. Disconnect the keyboard from the host device.
NSTALLATION ABLE NSTALLATION NTERFACE PECIFIC Stand Alone Keyboard IS1650-47 Turn off the host device. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS1650. There will be an audible click when the connector lock engages.
NSTALLATION ABLE NSTALLATION NTERFACE PECIFIC IBM 46xx IS1650-106 Turn off the host device. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the IS1650. There will be an audible click when the connector lock engages. Connect the other end of the MVC cable to the host device.
NSTALLATION ABLE NSTALLATION NTERFACE PECIFIC Integrated USB: Low Speed IS1650-38 Full Speed IS1650-106 Turn off the host device. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on the IS1650. There will be an audible click when the connector lock engages.
NSTALLATION TAND NSTALLATION PTIONAL Metrologic provides two #8 wood screws for securing the stand base to the counter top. The following figure provides the pilot hole dimensions for securing the stand base. Figure 13. Stand Base Hole Pattern (Not to Scale)
CANNER ONFIGURATION ONFIGURATION ODES The IS1650 Series scanner has three modes of configuration. • Bar Codes The IS1650 can be configured by scanning the bar codes included in the Metrologic Single-Line Configuration Guide ( 00-02544) or the MLPN Supplemental Configuration Guide ( 00-02281).
CANNER ONFIGURATION The IS1650 FocusE is part of Metrologic's line of scanners with flash upgradeable firmware. The upgrade process requires a new firmware file supplied to the customer by a customer service representative and Metrologic's MetroSet2 software . A personal computer running Windows 95 or greater with an available RS232 serial or USB port is also required to complete the upgrade.
CANNER PERATION ODES OF PERATION Presentation Mode, Fixed-Mount or In-Stand (Default) The IR detects an object in the IR activation range and the scanner’s light output automatically starts to flash as it attempts to scan the bar code. The scanner continuously attempts to scan the bar code until either it succeeds or the bar code is removed from the scanner’s field of view.
CANNER PERATION UDIBLE NDICATORS When the IS1650 is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the tone, refer to the MetroSelect Single-Line Configuration Guide, 00-02544 or MetroSet2’s MLPN...
CANNER PERATION ISUAL NDICATORS The IS1650 has three LED indicators (yellow, white and blue) located on the top of the scanner. When the scanner is on, the flashing or constant activity of the LEDs indicates the status of the current scan and the scanner. No LEDs are Illuminated The LEDs will not illuminate if the scanner is not receiving power from the host or transformer.
CANNER PERATION AILURE ODES Long Razzberry Tone – During Power Up Failed to initialize or configure the scanner. If the scanner does not respond after reprogramming, return the scanner for repair. Short Razzberry Tone – During Scanning An Invalid bar code has been scanned when in configuration.
CANNER PERATION EPTH OF IELD BY INIMUM LEMENT IDTH INIMUM LEMENT IDTH .132 .191 .254 .330 .533 .254 .381 mils 10.4 15.9 Figure 16. Depth of Field by Minimum Bar Code Element Width Specifications are subject to change without notice.
CANNER PERATION IR A CTIVATION ANGE The IS1650 has a built in object detection sensor that instantly turns on the scanner when an object is presented within the scanner’s IR activation Area. Figure 17. IR Activation Area Specifications are subject to change without notice...
AINTENANCE AILY AINTENANCE Smudges and dirt on the unit's window can interfere with the unit's performance. If the window requires cleaning, use only a mild glass cleaner containing no ammonia. When cleaning the window, spray the cleaner onto a lint free, non- abrasive cleaning cloth then gently wipe the window clean.
ROUBLESHOOTING UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited warranty terms. All Interfaces IS1650 Series Troubleshooting Symptom / Solution Chart Symptoms Possible Causes Solution No power is being Check transformer, outlet and supplied to the power strip.
Page 33
ROUBLESHOOTING UIDE Symptoms Possible Causes Solution The unit powers The beeper is up, but does not Enable the beeper and select a disabled and no tone beep when bar tone. is selected. code is scanned. UPC/EAN, Code 39, interleaved 2 The unit powers The bar code of 5, Code 93, Code 128, Codabar...
Page 34
ROUBLESHOOTING UIDE Symptoms Possible Causes Solution The bar code may Check if it is a check have been printed digit/character/or border problem. incorrectly. The unit beeps at some bar The scanner is not codes and NOT configured correctly Check if check digits are set for others of the for this type of bar properly.
Page 35
ROUBLESHOOTING UIDE Symptoms Possible Causes Solution Increase interscan code delay The unit is setting. Adjust whether the F0 transmitting The configuration is break is transmitted. It may be each character not set correctly. necessary to try this in both twice. settings.
EFAULT ETTINGS Many functions of the scanner can be “configured” – that is, enabled or disabled. The scanner is shipped from the factory configured to a set of default conditions. The default parameter of the scanner has an asterisk (*) in the charts on the following pages.
Page 37
EFAULT ETTINGS PARAMETER DEFAULT RS232 IBM 46XX & KEYBOARD Maxicode Aztec Postals Mod 43 Check on Code 39 MSI-Plessy 10/10 Check Digit MSI-Plessy Mod 10 Check Digit Paraf Support ITF ITF Symbol Lengths Variable Symbol Length Lock None Beeper tone Normal Before Beep/transmit sequence...
Page 38
EFAULT ETTINGS PARAMETER DEFAULT RS232 IBM 46XX & KEYBOARD Transmit lead zero on UPC-E Transmit UPC-A number system Transmit UPC-A Manufacturer ID# Transmit UPC-A Item ID# Transmit Codabar Start/Stop Characters CLSI Editing (Enable) Transmit Mod 43 Check digit on Code 39 Transmit Mod 10/ITF Transmit MSI-Plessy Parity...
Page 39
EFAULT ETTINGS PARAMETER DEFAULT RS232 IBM 46XX & KEYBOARD XON/XOFF Handshaking ACK/NAK Two Digit Supplements Five Digit Supplements Bookland 977 (2 digit) Supplemental Requirement Supplements are not Required Two Digit Redundancy Five digit Redundancy Coupon Code 128 † Configurable Code Lengths 7 avail †...
CANNER AND ABLE ERMINATIONS CANNER INOUT ONNECTIONS The IS1650 scanner interfaces IS1650-14 terminate to a 10-pin, RJ45 RS232 Female Socket. The serial # Function label indicates the interface Ground enabled when the scanner is RS232 Transmit Output shipped from the factory. RS232 Receive Input RTS Output CTS Input...
Page 41
CANNER AND ABLE ERMINATIONS CANNER INOUT ONNECTIONS IS1650-38 Low Speed USB Function Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input USB D+ V USB USB D- +5VDC Shield Ground IS1650-106 IBM 46xx / Full Speed USB Function Figure 19.
CANNER AND ABLE ERMINATIONS ABLE ONNECTOR ONFIGURATIONS “Standard” PowerLink Cable 59-59000-3, Straight Function Shield Ground RS232 Transmit Output RS232 Receive Input DTR Input/Light Pen Source Power/Signal Ground Reserved CTS Input 9-Pin D-Type Connector RTS Output +5VDC Stand Alone PowerLink Keyboard Cable 54-54020-3, Straight Function...
Page 43
CANNER AND ABLE ERMINATIONS ABLE ONNECTOR ONFIGURATIONS Keyboard Wedge Cable 59-59002-3, Straight Function Keyboard Clock Keyboard Data No Connect Power Ground 5-Pin DIN, Female +5 VDC Function PC Data No Connect Power Ground +5 VDC 6-Pin DIN, Male PC Clock No Connect Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other.
Page 44
EGULATORY OMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Class 1 LED Product: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Under no circumstances should the customer attempt to service the LED scanner.
Page 45
EGULATORY OMPLIANCE Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Class A Devices The following is applicable when the scanner cable is greater in length than 3 meters (9.8 feet) when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner dépassant 3 métres...
Page 46
EGULATORY OMPLIANCE Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner ne dépassant pas 3 métres (9.8 pieds) de long en extension maximale: Folgendes trifft zu, wenn das Scannerkabel kürzer als 3 Meter ist:...
ATENTS This METROLOGIC product may be covered by, but not limited to, one or more of the following U.S. Patents: U.S. Patent No.: 7,086,595, 7,128,266, 7,213,762, 7,216,810, 7,225,998, 7,225,989 No license right or sublicense is granted, either expressly or by implication, estoppel, or otherwise, under any METROLOGIC or third party intellectual property rights (whether or not such third party rights are licensed to METROLOGIC), including any third party patent listed above, except for an...
IMITED ARRANTY The IS1650 series scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The IS1650 series scanners have a five (5) year limited warranty from the date of manufacture. Metrologic warrants and represents that all IS1650 series scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S.