Canon 1000 Service Manual page 462

Color laser copier
Hide thumbs Also See for 1000:
Table of Contents

Advertisement

7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
6) Check that the basic setting is indicated on the
CST-AD screen under 'FUNC' in service mode
on the control panel.
7) Select the size for which you want to register
the basic setting.
MF-A6R
8) Note that basic setting 2 has been registered.
9) Set the paper guide plate of the multifeeder to
A4 (297 mm).
10) The basic setting is indicated on the CST-AD
screen under 'FUNC' in service mode on the
control panel.
11) Select the size for which you want to register
the basic setting.
MF-A4
12) Note that basic setting 3 has been registered.
7-26
COPYRIGHT © 2001 CANON INC.
If you have registered basic settings,
record the settings on the service la-
bel.
If you have replaced the DC controller
PCB, enter the settings recorded on
the service label using 'DC-CON' un-
der 'FUNC' in service mode.
A4/A3
A4R
STMT-R
STMT-R
(139.7mm)
CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
A4R
A4
(210mm)
(297mm)
Paper width
Figure 7-243

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000s3100