Sharp SF-2040 Service Manual page 116

Table of Contents

Advertisement

Main code
Sub code
26
01
Option unit setup
Used to set up option unit.
1 When the test command is executed, the presently stored machine setup code is displayed with the
2 After the READY lamp has turned on, enter an appropriate setup code on the keypad and press the
Code
+10
°
No need to set "+2 (ADU)". If the ADU is installed, "2" is automatically added.
°
Used to set the code that corresponds to an option unit.
(EX): To set the RADF and desk together with ADU, enter 1+2+4=7, or 1+4=5.
NOTES:
03
Coin vendor setting
0: Cancel, 1: Setting
26
05
Counter mode setup
1 When the test command is executed, the code of the presently stored mode is displayed with the
2 After the READY lamp has turned on, enter an appropriate setup code on the keypad and press the
06
Destination setup
Used to set the destination setting.
1 When the test command is executed, the presently stored model number and the destination code
2 After the READY lamp has turned on, enter the model number and the destination code on the
07
Drum sensitivity setup
1 When the test command is executed, the number stored in the memory is recalled and the READY
2 A number 1 to 3 may be entered on the keypad while the RPL is active.
3 Press the PRINT switch after the number has been entered. With this, the READY lamp turns off
°
Drum
Keypad entry
Sensitivity
READY lamp turned on.
PRINT switch. Then, the date is stored in the memory and the READY lamp turns off.
Option
0
No option
+1
RADF
+2
ADU
+4
Desk
Sorter
(1) Be sure to enter the code that corresponds to the installed option unit.
(2) If option setup is incorrect, a trouble code is displayed. See the trouble code chart.
READY lamp turned on.
PRINT switch. Then, the code is stored in the memory and the READY lamp turns off.
Code
Total counter
0
Double count
1
Single count
2
Double count
3
Single count
are displayed (see table below) and the READY lamp turns on.
keypad and press the PRINT switch to store the setting in the memory. The READY lamp then
turns off.
Code
Destination
0
SEC (ES)
1
SEC
* America
2
SECL
3
Other
4
Japan
5
Other
6
SEEG
7
SUK
8
SCA
9
Other
* Energy star
lamp turns on.
and the test command number is displayed.
1
2
3
1
2
3
Description
Maintenance counter
Double count
Double count
Single count
Single count
AB/Inch
America
(Inch)
Canada
(AB Japan)
German
U.K.
(AB Export)
Australia
8 – 10
Ref. Page

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sf-d23Sf-dm11

Table of Contents