Main code
Sub code
08
01
Developing bias voltage output. After delivering the output, the machine automatically goes into the sub
code input wait state.
This is the test command used to check the developing bias voltage. The developing bias voltage is
turned on for 30 seconds.
Standard developing bias setting is –300VDC.
02
Main (charge) corona output [ME]. After delivering the output, the machine automatically goes into the
sub code input wait state.
Standard manual exposure mode main corona grid voltage is –860±15V.
This is the test command used to check the main corona variance between the front and rear sides.
The corona output continues for 30 seconds.
The main corona variance must be within 8µA between the front and the rear.
03
Main corona output [PE]. After delivering the output, the machine automatically goes into the sub code
input wait state.
Standard photographic mode main corona grid voltage is –610±15V.
04
Main corona output [TSM]. After delivering the output, the machine automatically goes into the sub code
input wait state.
Standard TSM main corona grid voltage is –755V±15V.
06
Transfer corona output [TSM]. After delivering the output, the machine automatically goes into the sub
code input wait state.
This is the test command used to check the transfer corona output (THV). The transfer corona output
continues for 30 seconds.
Standard transfer corona output is –57µA±4µA (F/R difference: Max. 5µA).
07
Separation corona output. After delivering the output, the machine automatically goes into the sub code
input wait state.
This is the test command used to check the separation corona output (SHV). The separation corona
output continues for 30 seconds.
Standard separation corona output is –100±10 V.
09
02
ADU sensor check test command ON/OFF state of each sensor can be manually checked.
When the sensor turns on, the display reverses.
03
ADU trail edge plate drive motor rotation
Used to check the trail edge plate movement
(AB series)
HP.A3
(Inch series)
HP.11" x 17"
04
ADU alignment plate drive motor rotation
Used to check the alignment plate movement
(AB series)
HP.A3
(Inch series)
HP.11" x 17"
05
Gate solenoid activation
Used to check the gate solenoid operation.
THV
SHV
Sensor
Function
DPPD1
ADU transport sensor 1
DPPD2
ADU transport sensor 2
DTPID
ADU tray sensor
DPFD
ADU tray out sensor
APHPS1
ADU alignment plate home position sensor
APHPS2
ADU rear edge plate home position sensor
B4
A4R
B5R
1
11" x 14"
8
"
2
B4
A4R
B5R
1
11" x 14"
8
2
Description
30 sec
30 sec
A4
B5
A5
1
x
11"(R)
8
"
x
11"
2
A4
B5
A5
1
"
x
11"(R)
8
"
x
11"
2
8 – 7
Ref. Page
[7]-2(3)
[7]-5-(D)
[7]-5-(D)
[7]-5-(D)
[7]-4-(B)
[7]-6-(E)