8.15 Trouble Conditions

Trouble Conditions (Level 1) are comprised of various trouble types (Level 2) which may in turn be related to a specific zone,
module, device or additional type of system equipment (Level 3). For an explanation of possible trouble conditions and the recom-
mended actions required.
When the system detects a trouble condition the following occurs:
The Trouble indicator turns on.
l
The keypad beeps once every 10 seconds.
l
Press the [*] key to silence the keypad beeps.
l
Examining troubles is done by pressing [*][2]. When viewing troubles, the trouble indicator flashes to identify the level of trouble
being viewed. One flash = level 1, two flashes = level 2 etc.
Arming of your system may be impeded by a trouble. To override this condition, enter [*2] and scroll to acknowledge all troubles
and press [*] or enter 999.
Trouble
Trouble
#
Description
Condition
Level 1
Note: Trouble #s are used to identify the number to view the trouble and depending on the keypad type being used, identifies
which LED or digit illuminates to display the trouble. Similarly, Trouble Notification identifies the range that may be displayed
on the keypad. When exploring the trouble levels, the Trouble indicator will flash to identify which level you are currently view-
ing.
Service
01
Assorted Trouble types.
Time and Date troubles can be resolved by resetting the
Required
Time/Date. To set Time/Date press [*][6][0][1]. For all
other troubles call for service.
Battery Trouble 02
The system has detected a battery trouble condition. Call
for service.
Bus Voltage
03
A module has detected a low voltage on its corbus red ter-
minal.
Trouble
Types
Bell Circuit
RF Jam
Auxiliary Sup-
ply
Loss of clock 04
Output 1 Fault 05
Low Battery
(System
Label)
No Battery
service (Sys-
tem Label)
High Current
Output Low
Battery
High Current
Output No Bat-
tery
Power Supply
Low Battery
Power Supply
No Battery
HSM2HOST
Keypad
Zone
Expander
Power Supply 05
High Current
Output
Output
Expander
HSM2955 Bus
Voltage
(Audio
Expander)
- 29 -
Trouble
Trouble
#
Notification
Level 2
Level 3
01
 
02
 
03
 
 
 
01
n/a
02
n/a
04
Module 1-4
05
Module 1-4
07
Module 1-4
08
Power supply
1-4
01
n/a
02
Keypad 1-16
04
Zone
expander 1-
15
Power supply
1-4
06
Output ter-
minal 1-4
08
Output mod-
ule 1-16
09
n/a