6-2. Operation Data

<Cooling>
Temperature
condition (°C)
Indoor
Outdoor
27/19
35/−
<Heating>
Temperature
condition (°C)
Indoor
Outdoor
20/−
7/6
Note :
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
(2) Connecting piping condition : 5m
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
1.1
13.5
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
2.4
40
− 19 −
FILE NO. SVM-05026
Indoor
Outdoor
fan
mode
mode
T2 (°C)
High
High
49
Indoor
Outdoor
fan
mode
mode
T2 (°C)
High
High
0
Compressor
fan
revolution
(rps)
54
Compressor
fan
revolution
(rps)
70