Toshiba RAS-10NKV-E Service Manual page 61

Split wall type
Table of Contents

Advertisement

10-8-3. Indoor unit (Other parts)
No.
Part name
Room temp. (TA) sensor
1
Heat exchanger (TC) sensor
Remote controller
2
Louver motor
3
24BYJ48
10-8-4. Outdoor unit
No.
Part name
Compressor
1
(Model : DA89X1F-23F)
Outdoor fan motor
2
(Model : HF-240-20B-2)
Compressor thermo. Bimetal
3
type (Model : PW - 2AL)
Outdoor temperature sensor
4
(TO), outdoor heat exchanger
temperature sensor (TE)
Checking procedure
Disconnect the connector and measure the resistance value with
tester. (Normal temp.)
Temperature
Sensor
TA, TC (kΩ)
To item of How to judge whether remote controller is good or bad of
the Judgement of trouble by symptom.
Measure the resistance value of each winding coil by using the
tester. (Under normal temp. 25°C)
White
1
Yellow
2
Yellow
3
Yellow
4
Yellow
5
Checking procedure
Measure the resistance value of each winding by using the tester.
Red
White
Black
Measure the resistance value of winding by using the tester.
Red
Red
1
4
Black
2
5
Black
White
3
6
White
1 : White 4 : −
2 : −
5 : −
3 : Red
6 : Black
Check conduction by using the tester.
Disconnect the connector, and measure resistance value with the
tester. (Normal temperature)
TGa : Heat pump model only.
TO, TE : Refer to the TA, TC characteristic table in Indoor (Refer to
Table 10-8-3, No.1).
– 60 –
FILE NO. SVM-05026
10°C
20°C
25°C
20.7
12.6
10.0
Position Resistance value
1 to 4
1 to 6
2 to 3
2 to 5
Position
Resistance value
Red - White
White - Black
Black - Red
Position
Resistance value
Red - White
White - Black
Black - Red
For details, refer to Section 10-9.
30°C
40°C
7.9
4.5
130 ± 10Ω
1.1Ω
1.1Ω
1.1Ω
Under 20°C
720 ~ 920Ω
410 ~ 510Ω
310 ~ 410Ω
At 20°C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10nav-eRas-10nkv-aRas-10nav-a

Table of Contents