Hall Adjustment; Flange Back Adjustment - Sony MVC-FD91 Service Manual

Digital mavica
Hide thumbs Also See for MVC-FD91:
Table of Contents

Advertisement

2. HALL Adjustment

For detecting the position of the lens iris, adjust the hall AMP gain
and offset.
Subject
Not required
Adjustment Page
F
Adjustment Address
C7, C8
Note: Check that the data of page: 2, address: 02 is 00. If not, select page:
2, address: 01, set data: 00 and press the PAUSE button of the
adjustment remote commander.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 6D, and press the PAUSE
button of the adjustment remote commander. (The HALL
adjustment is performed and the adjustment data is stored in
page: F, address: C7, C8 and page: E, address: 1E.)
3)
Select page: 2, address: 02, and check that the data is "01".
Processing after Completing Adjustments
1)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.

3. Flange Back Adjustment

The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
E
1E
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Adjusting method:
1)
2)
3)
Address
4)
5)
6)
7)
Processing after Completing Adjustments
1)
2)
5-11
Flange back adjustment chart
(2.0 m from the front of the protection
glass)
(Luminance: 350 ± 50 lux)
Check operation on LCD screen
F
B6 to BB, BE to C5
Check that at both the zoom lens TELE end and WIDE end,
the center of the chart for the flange back adjustment and center
of the exposure screen coincide.
Select page: 0, address: 01, and set data: 01.
Check that the data of page: F, address: B6 to BB, BE to C5 is
the initial value (See table below).
Data
B6
56
B7
19
B8
E0
B9
21
BA
E7
BB
11
BE
00
Select page: 2, address: 02, and check that the data is "00".
Select page: 2, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
Select page: 2, address: 01, set data: 15, and press the PAUSE
button of the adjustment remote commander.
(The adjustment data will be automatically input to page: F,
addresses: B6 to BB, BE to C5.)
Select page: 2, address: 02, and check that the data is "01".
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
Select page: 0, address: 01, and set data: 00.
Address
Data
BF
00
C0
23
C1
00
C2
19
C3
00
C4
11
C5
00

Hide quick links: