9. White Balance Check

Subject
Clear chart
(Color bar standard picture frame)
Filter
ND filter 1.0 and 0.3
Measurement Point
Display data of page: 1
Measuring Instrument
Adjustment remote commander
Specified Value
R-Y data:
B-Y data:
Light level data:
Note 1: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Note 2: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Checking method:
1)
Check that the lens is not covered with the ND filter.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: E, address: 11, set data: 15, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 0, address: 03, and set data: 02.
5)
Select page: 2, address: 10, and set data: 58.
6)
Select page: 2, address: 56, and set data: 56.
7)
Select page: 2, address: 01, set data: 0F, and press the PAUSE
button.
8)
Select page: 1, and check that the R-Y data satisfies the specified
value and the B-Y data satisfies the specified value. (Note1)
9)
Select page: 0, address: 03, and set data: 06.
10) Select page: 1, and check that the light level data satisfies the
specified value. (Note2)
11) Place the ND 1.3 filter on the lens.
12) Select page: 1, and check that the light level data satisfies the
specified value. (Note2)
Processing after Completing Adjustments
1)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 2, address: 10, and set data: 00.
3)
Select page: 2, address: 56, and set data: 00.
4)
Select page: E, address: 11, set data: 18, and press the PAUSE
button.
5)
Select page: 0, address: 01, and set data: 00.
6)
Select page: 0, address: 03, and set data: 00.
FC to FF or 00 to 04 (Note1)
FC to FF or 00 to 04 (Note1)
Without ND filter:
0E10 or more (Note2)
With ND filter 1.3:
0D00 or less (Note2)
R-Y data
B-Y data
Light level data

10. Strobe Light Level Adjustment

Adjust the minimum gain when the strobe light flashes.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note: Displayed data of page 1 of the adjustment remote commander.
1 :XX:XX
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: E, address: 70, set data: 03, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: E, address: 71, set data: 00, and press the PAUSE
button.
4)
Select page: 2, address: 10, and set data: 58.
5)
Select page: 2, address: 01, set data: 9D, and press the PAUSE
button.
6)
Select page: 1, and read the display data (Note). If the display
data lies within the "0207" to "0247" range, perform
"Processing after Completing Adjustments".
7)
Select page: E, address: 81, change the data, and press the
PAUSE button.
8)
Select page: 1, and check that the display data lies within the
"0207" to "0247" range. If not, repeat steps 7) to 8).
9)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button.
10) Select page: 2, address: 01, set data: 9D, and press the PAUSE
button.
11) Select page: 1, and check that the display data satisfies the
specified value.
Processing after Completing Adjustments
1)
Select page: E, address: 70, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: E, address: 71, set data: 00, and press the PAUSE
button.
3)
Select page: 0, address: 01, and set data: 00.
4)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
5)
Select page: 2, address: 10, and set data: 00.
5-15
Clear chart
(Color bar standard picture frame)
Display data of page : 1
Adjustment remote commander
E
81
01E7 to 0267
Object data