1-4.

CAMERA SYSTEM ADJUSTMENTS

Before perform the camera system adjustments, check that the
specified values of "VIDEO SYSTEM ADJUSTMENT" are
satisfied.
Note: If "CLOCK SET" display appeared in the screen after the power is
turned on, set the clock, or cancel the display.
Data Setting during Camera System Adjustments
Perform the following data setting before the camera system
adjustments.
1) Select page: 0, address: 01, and set data: 01.
2) Input the following data.
Page
Address
B
75
Note: Press the PAUSE button each time to set the data.
After completing the camera system adjustments, release the data
setting.
1) Select page: 0, address: 01, and set data: 01.
2) Input the following data.
Note: Press the PAUSE button each time to set the data.
Page
Address
B
75
3) Select page: 0, address: 01, and set data: 00.
SET UP Setting during Camera System Adjustments
VIDEO OUT (SETUP2) ....................... NTSC (NTSC mode)
Data
00
Data
10

1. HALL Adjustment (MVC-CD200)

For detecting the position of the lens iris, adjust the hall AMP gain
and offset.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
Note2: If the data of page: 6, address: 02 is "01", select page: 6, address:
01, set data: 00, and press the PAUSE button.
Adjusting method:
Order Page Address Data
1
0
01
2
6
94
3
6
95
4
6
01
5
6
02
6
6
01
Note3: The adjustment data will be automatically input to page: F, address:
2E, 2F, 34, 35.
Checking method:
Order Page Address Data
1
0
03
2
6
01
3
1
4
6
01
5
1
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
2
6
94
3
6
95
4
0
03
5
0
01
5-12
RadarW
RadarW
RadarW
Still (Auto (
))
Arbitrary
Display data of page 1 (Note1)
Adjustment remote commander
F
2E, 2F, 34, 35
12 to 16 during IRIS OPEN
77 to 7B during IRIS CLOSE
Display data
Procedure
01
Set the data.
14
Set the data.
79
Set the data.
6D
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note3)
00
Set the data, and press PAUSE
button.
Procedure
03
Set the data.
01
Set the data, and press PAUSE
button.
Check that the display data (Note1)
satisfies the specified value 1.
03
Set the data, and press PAUSE
button.
Check that the display data (Note1)
satisfies the specified value.2.
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data.

Advertisement

Table of Contents
loading